No.
Evaluation mode
Description
8
Best circle diameter [default]
The circle with the smallest difference to the target value
that was set for the
Circle diameter [mm]
parameter is
used for the output of measured values. This evaluation
mode is the default.
9
Target region - best circle diam‐
eter
Only circles within the target region will be used for the
evaluation. The circle with the smallest difference to
the target value that was set for the
Circle diameter [mm]
parameter is used for the output of measured values.
10
Target region - first circle left
Only circles within the target region will be used for the
evaluation. The circle with the smallest distance from
the left edge of the image is used for the output of
measured values. This is the circle with the smallest
value for the
Automated storage and retrieval system relative
position correction X
parameter.
11
Target region - first circle right
Only circles within the target region will be used for the
evaluation. The circle with the smallest distance from
the right edge of the image is used for the output of
measured values. This is the circle with the largest value
for the
Automated storage and retrieval system relative position
correction X
parameter.
12
Target region - first circle top
Only circles within the target region will be used for the
evaluation. The circle with the smallest distance from
the top edge of the image is used for the output of meas‐
ured values. This is the circle with the smallest value
for the
Automated storage and retrieval system relative position
correction Y
parameter.
13
Target region - first circle bot‐
tom
Only circles within the target region will be used for the
evaluation. The circle with the smallest distance from
the bottom edge of the image is used for the output of
measured values. This is the circle with the largest value
for the
Automated storage and retrieval system relative position
correction Y
parameter.
14
Target region - no output for
multiple circles
Only circles within the target region will be used for the
evaluation. If there are several circles within the target
region, no output of measured values occurs.
1)
The measured score value specifies how well the located circle corresponds to an ideal circle. The
measured score value is displayed at the top of the live image in SOPASair.
Further topics
•
6.5.11
Setting the evaluation mode
Procedure
1.
Set the user level to
Maintenance
.
2.
Open the
Advanced setup
window.
3.
Select an evaluation mode in the drop-down menu of the
Selection
parameter.
Further topics
•
•
Setting the evaluation mode using a command:
Commands from the controller to
COMMISSIONING
6
8024534/1DQ8/2022-01-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | InspectorP Rack Fine Positioning
25
Subject to change without notice