Wire “Result 1 ... 4” switching outputs of the CLV69x in the CDM490-0001 connection module
CLV69x
CDM490-0001
(I/O card)
U
V
= DC 18 ... 30 V
Load (e.g. PLC)
Cable, e.g.
No. 2020302 (3 m)
Y
5
.
.
.
Z
Name
45
GND
5
Shield
+24 V* (U
V
)
U
V
GND
Sweep-out circuit:
Attach a freewheeling diode
directly to the load.
With inductive load:
U
a
Result X
Result X
GND
Y
5
1
1
Characteristic data of “Result 1 ... 4“ switching outputs
PNP switching to supply voltage
U
V
(+24 V*).
CLV69x default settings:
Result 1: device ready (static), logic: active high
Result 2: good read, 100 mm, logic: active high
Result 3: no function assigned
Result 4: no function assigned
– Short-circuit pro temperature protected
– Not electrically isolated from U
V
(+24 V*)
0 V ≤ U
a
≤ U
V
Guaranteed:
(U
V
− 1.6 V) ≤ U
a
≤ U
V
at I
a
≤ 100 mA
Switching
behavior
Properties
Electrical
values
2
“I/O” connection
2
6
1
10
5
11
15
10 5
6
1
15
11
D-Sub-HD
CDM490-0001
CLV69x
Terminal Z
41
42
43
44
Name
Result 1
Result 2
Result 3
Result 4
Pin Y
4
8
10
15
Pin Y
4
8
10
15
Result X
Result 1
Result 2
Result 3
Result 4
Result X
Result 1
Result 2
Result 3
Result 4
Figure 76: Wiring switching outputs “Result 1 to 4”
6
ELECTRICAL INSTALLATION
82
O P E R A T I N G I N S T R U C T I O N S | CLV69x
8014396/ZMG8/2017-07-04 | SICK
Subject to change without notice