Operating Instructions
Chapter
6
CLV 42x bar code scanner
Operation
8 009 981/O078/16-08-2004
©
SICK AG · Division Auto Ident · Germany · All rights reserved
6-7
•
Type of logical data network of connected CLVs
•
Use of switching inputs/outputs of the CLV as CANopen Digital I/O
Fieldbus Gateway
This tab (and additional dialog boxes) are used to set the following:
•
Data interface of the CLV to be connected to the gateway in the CDM 420
•
Type of fieldbus
•
Special fieldbus parameters
Extras
This tab is used to edit parameters that were not recognized by CLV Setup after an upload.
Note
The online "CLV Setup Help" contains a detailed description of the functions of the
parameters and their valid entries.
See
Chapter 10.4.8 Online help – CLV Setup Help,
6.4.3
Parameterization guide
Overview of parameterization procedure
•
Parameterize optical reading characteristics of the scanner
•
Set up reading pulse
•
Parameterize the evaluation characteristics of the decoder
•
Parameterize output characteristics (data, result status)
•
Define the function of the terminal interface
When the CLV is started up for the first time, the
factory default settings
are in effect. The
following parameters must then be set:
a) Parameterizing optical reading characteristics
•
Scanning frequency R
EADING
C
ONFIGURATION
tab R
EADING
P
ARAMETERS
section
•
Min. reading distance R
EADING
C
ONFIGURATION
tab M
INIMUM
D
ISTANCE
section
•
Quiet zone R
EADING
C
ONFIGURATION
tab Q
UIET
Z
ONE
section
•
Poor quality bar code print R
EADING
C
ONFIGURATION
tab C
ODELABEL
Q
UALITY
section.
Alternative: Enable Dynamic Reading Configuration R
EADING
C
ONFIGURATION
tab
D
YNAMIC
R
EADING
C
ONFIGURATION
ACTIVE
•
Limite evaluation range of scan line R
EADING
C
ONFIGURATION
tab
C
ODE
P
OSITION
section