Loading complete parameter set from the CLV (upload)
Click
in the toolbar.
CLV Setup loads the current CLV parameter set from the RAM of the CLV to its database
and displays the values on the tabs.
The "Device Ready" LED is extinguished during the upload.
If the "CLV Setup" program does not recognize the parameters transferred during the
upload, it outputs a warning. Unknown parameters can be edited on the E
XTRAS
tab by
following the conventions for command strings. When the parameter set is saved, these
parameters are also taken into account.
Transferring the complete parameter set to the CLV and saving it (download)
1.
Click
in the toolbar.
The "Device Ready" LED is extinguished.
CLV Setup copies the parameter set to the RAM of the CLV.
The D
OWNLOAD
P
ARAMETERS
dialog window with the save options is then displayed.
P
ERMANENT
:
CLV Setup copies the parameter set to the RAM and to the EEPROM of
the CLV.
T
EMPORARY
:
CLV Setup copies the parameter set to the RAM only. The changes are
lost when the CLV power supply is switched off.
2.
Confirm the dialog box with the desired save option.
The "Device Ready" LED lights up again.
The new parameter set is saved in the CLV, permanentely or temporarily dependent on the
selected option.
Saving the parameter set in CLV Setup
1.
To save the modified parameter set as a new configuration file in CLV Setup, or to
overwrite an existing file, choose F
ILE
and S
AVE
A
S
.
The S
AVE
AS
dialog window is then displayed.
2.
Enter the file name in the dialog window (file extension "*.scl") and confirm the entry.
The new parameter set is now saved in CLV Setup in the subdirectory "data".
6.4.2
Function of tabs in CLV Setup (overview)
Reading Configuration
This tab (and additional dialog windows) are used to set the following:
•
Scanning frequency and min. reading distance
•
Quiet zone
•
Adapting the reading function to the quality of the bar code
•
Limitation of the evaluation range of the scan line
•
Activation of dynamical reading configurations
Device Configuration
This tab (and additional dialog windows) are used to set the following:
•
Device number
•
Source of the reading pulse
•
Output time of the reading result referred to the start of the reading pulse
•
Laser timeout
•
Encoder parameters