Operating Instructions
Chapter
8
CLV 42x bar code scanner
Troubleshooting
8 009 981/O078/16-08-2004
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8-7
8.5.3
Malfunctions in reading mode: result output errors
Check whether the "Device Ready" LED illuminates.
If the LED does not illuminate, follow
For the following, the number of bar codes to be read is 1.
Malfunction
Possible cause
Remedy
1.
The "Result" LED
(default setting: "Good read") does not
light up at the end of the reading pulse.
– The "Result 2" switching output
(default setting: "Good read") is
not outputting a pulse
– The CLV outputs the status ST = 2
in the reading result on the host
interface (if ST is enabled for the
separator; this is not selected in
the default setting)
•
Read not successful, since there was no
bar code in the reading field during the
reading pulse
•
Scan line positioned incorrectly
•
Evaluation range of the scan line is
limited improperly (CP values)
•
Bar code presented at incorrect reading
distance
•
The bar code is tilted excessively with
respect to the scan line
•
The reading angles at which the bar code
appears to the CLV are too large
•
Bar code is in total reflection zone
•
Synchronize reading with an object in the
reading field.
See
reading mode: reading pulse errors,
Page 8-6
•
Align CLV.
Is bar code at center of scan line?
In the CLV Setup program: check reading
quality. Choose P
ERCENTAGE
E
VALUATION
.
See
Chapter 6.5.2 Percentage evalua-
.
•
In the CLV Setup program: Check by
choosing the R
EADING
C
ONFIGURATION
tab,
C
ODE
P
OSITION
group: are the min. and
max. code position values correct?
Check with S
HOW
CP-
LIMITS
.
See
.
•
Check: reading distance of bar code in
specified reading range?
•
Align bar code accordingly.
•
In the CLV Setup program: Start
P
ERCENTAGE
E
VALUATION
, select D
ISTANCE
C
ONFIGURATION
(if used).
Monitor reading quality (reading quality
>70 %!).
Realign CLV if necessary.
•
Optimize CLV alignment (scan line should
strike the bar code at an skew of approx.
15
°
).
In the CLV Setup program: check reading
quality. Start P
ERCENTAGE
E
VALUATION
.
See
Chapter 6.5.2 Percentage evaluation,
Page 6-17
.
Table 8-5: Troubleshooting: result output errors in reading mode