Module number
Total size
Module type
Contents
Designation
Type
Value range
22
Empty
Parameter mod‐
ule
Preset Static [mm]
Parameter
–300,000 ...
300,000
23
Empty
Parameter mod‐
ule
Offset [mm]
Parameter
–600000 ...
300000
25
Empty
Parameter mod‐
ule
Average Filter Distance Parameter
fast, medium, slow
Average Filter Speed
Parameter
fast, medium, slow
Error Rejection
Parameter
off, 50 ms, 200 ms
Heating Threshold
[degC]
Parameter
–10 ... 40
Frequency Set
Parameter
Mode 0, mode 1
Mode 2, mode 3
26
Empty
Parameter mod‐
ule
Free Distance Resolu‐
tion
Parameter
1 … 100,000
27
Empty
Parameter mod‐
ule
Free Velocity Resolution Parameter
1 … 100,000
28
Empty
Parameter mod‐
ule
Measurement Direction Parameter
positive direction
[+], negative direc‐
tion [-]
device information module overview
Table 31: device information module overview
Module number
Total size
Module type
Contents
Designation
Type
Size
30
8 bytes
Input module
Serial no
Input
8 characters
31
9 words
Input module
Product Code
Input
14 characters
Reserved
Input
4 bytes
32
8 bytes
Input module
HW version
Input
8 characters
33
10 words
Input module
FPGA version
Input
12 characters
Reserved
Input
8 byte
34
10 words
Input module
uC version
Input
12 characters
Reserved
Input
8 bytes
35
10 words
Input module
Version uC2
Input
12 characters
Reserved
Input
8 bytes
10.3
Module description
10.3.1
Module 1:
Distance /i2w
Type
Input module, 2 words, consistent
Description
This module reads the current distance value.
PROFIBUS INTERFACE
10
8014755/19H8/2021-10-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
59