13.3
Supply
Table 43: Supply
Supply voltage V
S
18 V DC … 30 V DC, reverse polarity protected
Current consumption (with‐
out load)
■
Without heating: < 250 mA at 24 V DC
■
With heating: < 1,000 mA at 24 V DC
Residual ripple
< 5 V
SS
within the permissible supply voltage U
V
13.4
Inputs
Table 44: Inputs
Inputs
Multifunctional input MF1, switching function adjustable
Switching type: Source for PNP output (open input corresponds to
the LOW input signal)
■
HIGH > 12 V
■
LOW < 3 V
Circuit protection
None, no reverse-polarity protection.
13.5
Outputs
Table 45: Outputs
Outputs
Multifunctional outputs MF1 and MF2, type B (push/pull), adjusta‐
ble switching function
■
HIGH > U
V
– 3 V
■
LOW < 2 V
Circuit protection
■
Short-circuit protected
■
Overload-proof
Maximum output current
Max. 100 mA
Output load
■
Capacitive: 100 nF
■
Inductive: 20 mH
13.6
Interfaces
Table 46: Interfaces
Process data interface
PROFIBUS DP V0
Ethernet
Configuration/Service interface (SOPAS ET)
13.7
Ambient data
Table 47: Ambient data
Protection class
Suitable for operation in PELV (Protective Extra Low Voltage) sys‐
tems with safe separation.
Electromagnetic compati‐
bility
EN 61000-6-2, EN 61000-6-4, Class A
Ambient operating temper‐
ature range
–20 ... +55 °C
2)
–40 ... +55 °C (with integrated heating)
3)
-20 ... +75 °C (with cooler housing TPCC)
TECHNICAL DATA
13
8014755/19H8/2021-10-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
87
Subject to change without notice