Icon
Description
Esc
Set
Menu
MEN
The
MEN
symbol is displayed in “menu display” operating
mode. In this operating mode, device parameters can be read
out or set depending on the interface.
When it comes to setting parameters in devices with fieldbus
interface, make sure to observe the notes in
NOTE
In the display, distance values always have the resolution “mm”, speed values the reso‐
lution “mm/s”. Positive numerical values do not have a sign, negative numerical values
have the “-” sign. This limits the display range to 5 decimal places when numerical
values are negative. In the “measured value display” operating mode, the sign and
the highest decimal place are cut off and replaced by a "!" when the value -99,999 is
undercut.
3.4.3
Operating pushbuttons
The device can be operated using the following 4 pushbuttons:
Table 4: Pushbuttons
Button
Description
■
Scroll through process values or (main) menu
■
Reduce value
■
Scroll through process values or (main) menu
■
Increase value.
■
Enter menu operation
■
Switches to the next lower menu level
■
Confirm selection
■
Leave value/option input of a parameter without saving.
■
Jump back to the next highest menu level or to the measured value display.
3
FUNCTION AND USE
16
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
8014755/19H8/2021-10-15 | SICK
Subject to change without notice