Name
Description
[MF1 Service] Laser
Warning
The output switches when the aging of the laser diode means that the
device is nearly due to be replaced.
Options
•
off
•
on
Factory setting
•
on
[MF1 Service] Level
Warning
The output switches when the signal attenuation value reaches the criti‐
cal value, for example due to contamination.
Options
•
off
•
on
Factory setting
•
on
[MF1 Service] Temp.
Warning
The output switches when the interior device temperature reaches the
critical value.
Options
•
off
•
on
Factory setting
•
on
[MF1 Service] Plausib.
Warning
The output switches if extrapolated measured values are to be output for
implausible measured values
ErrRej
.
This may be caused by an internal error, hardware errors, obstruction of
the light beam, optical interference or electrical interference.
Options
•
off
•
on
Factory setting
•
on
[MF1 Service] Not
Ready
The output switches when the device is not ready for operation. Possible
causes could be hardware errors, optical or electrical interference or
a deactivated laser diode. This warning message is also issued during
initialization.
Options
•
off
•
on
Factory setting
•
on
[MF1 Service] Heating
Status
The output switches if the internal device heater is in operation.
Options
•
off
•
on
Factory setting
•
on
PROFIBUS INTERFACE
10
8014755/19H8/2021-10-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
71