Formula
a ≥ 0.1 m + 0.01 x s
max
[m]
Example
■
Maximum travel distance s
max
: 60 m
■
Calculation of minimum distance: a ≥ 0.1 m + 0.01 x 60 m = 0.1 m + 0.6 m =
0.7 m
Configurable modulation frequency
If the required minimum distance cannot be observed, then devices from the Dx100
series are available which are equipped with configurable modulation frequencies for
avoiding mutual interference. These devices can be mounted without any minimum
distance of separation from each other and are identified in the type code using the
letter
B
(e.g. DL100-21A
B
2101). There are 3 modulation frequencies available
5.5
Arranging the distance sensor to the adjacent optical data transmission system
5.5.1
Arrangement of ISD400-7xxx
Dx100-2xxAxxxx
For arrangement and the travel distance from the DL100-2xxAxxxx distance sensor (or
the DL100-2xxBxxxx up to serial number 1925xxxx) without integrated spectral to the
ISD400-7xxx data transmission system, the following applies:
a
1
2
4
3
S
et
Es
c
<
<
s
m
ax
.
a > s
max
x 0,0083
Figure 10: Arrangement of distance sensor DL100-2xxAxxxx to data transmission system
ISD400-7xxx
1
DL100-2xxAxxxx distance sensor
2
Reflector
3
ISD400-7xx1, red
4
ISD400-7xx2, infrared
a
Minimum distance
s
max
Maximum travel distance
Formula:
a ≥ 0.0083 x s
max
MOUNTING
5
8014755/19H8/2021-10-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFIBUS DP
23
Subject to change without notice