sibility and at the charge of the customer.
- The electric hook-up must be performed according to:
• absorbed power specifications indicated on the machine dataplate.
• the distance between the machine and the electric hook-up point, so that voltage drops
under full load do not exceed 4% (10% when starting up) of the rated voltage specified
on the data plate.
- The user must:
• fit a plug that respects the current regulations onto the power supply cable;
• connect the machine to its own electrical connection fitted with a suitable 30-mA current
sensitive circuit breaker;
• fit power supply protection fuses sized in compliance with specifications in the main
wiring diagram of this manual;
• provide the workshop electric installation with an efficient grounding circuit.
- prevent unauthorised use of the machine, always disconnect the power supply plug when
the machine is not used (switched off) for extended periods of time.
- If the machine is connected directly to the power supply by means of the main electrical
board and without the use of a plug, install a key-operated switch or suitable lock-out
device to restrict machine use exclusively to qualified personnel.
CAUTION
For the machine correct functioning it is vital to have a good ground connection. NEVER
connect the machine ground wire to a gas pipe, water pipe, telephone cable or any other
unsuitable object.
COMPRESSED AIR HOOK-UP
CAUTION
All compressed air hook-ups must be carried out by qualified personnel only.
- The hook-up to the workshop's pneumatic system must ensure a minimum pressure of
7 bar (100 psi). Lower pressure levels may prevent the machine's AUTOMATIC WHEEL
LOCKING SYSTEM C from working properly.
- A universal union is used for connection to the compressed air system. No special or
additional adaptor is needed for connection. A pressure-resistant hose with 6mm inner
diameter and 14mm outer diameter must be fastened to the notched union using the
clamp provided with the machine.
Summary of Contents for S 65 E
Page 69: ...Manuale d uso S 65 E S 65 E C 69...
Page 70: ...70 Manuale d uso S 65 E S 65 E C SCHEMA PNEUMATICO Alimentazione Aria 7 10 bar 100 145 psi...
Page 71: ...Manuale d uso S 65 E S 65 E C 71 Note...
Page 72: ...72 Manuale d uso S 65 E S 65 E C Note...
Page 139: ...Operator s Manual S 65 E S 65 E C 139...
Page 140: ...140 Operator s Manual S 65 E S 65 E C PNEUMATIC DIAGRAM Air supply 7 10 bar 100 145 psi...
Page 208: ...208 Manuel d utilisation S 65 E S 65 E C...
Page 210: ...210 Manuel d utilisation S 65 E S 65 E C Remarques...
Page 279: ...Benutzerhandbuch S 65 E S 65 E C 279...
Page 280: ...280 Benutzerhandbuch S 65 E S 65 E C PNEUMATIKSCHEMA Luftversorgung 7 10 bar 100 145 psi...
Page 348: ...348 Manual de uso S 65 E S 65 E C...
Page 349: ...Manual de uso S 65 E S 65 E C 349 ESQUEMA NEUM TICO Alimentaci n Aire 7 10 bar 100 145 psi...
Page 350: ...350 Manual de uso S 65 E S 65 E C Notas...
Page 351: ......