background image

Deutsch 

 

ANWENDUNGSBEREICH: 

Die  Schwimmbeckenpumpen  der  Serie  SP  sind  für  die  Bewegung  von  sauberem  Süßwasser  und  ausschließlich  zur 

Privatnutzung gedacht. 

 

Bei unzweckmäßigem, nicht ausdrücklich vom Hersteller genehmigten Gebrauch, übernimmt der Hersteler keine 
Haftung. 

 

TECHNISCHE EIGENSCHAFTEN: 

 

Technische 

Eigenschaften  

230V - 50Hz

 

SP4000 

SP6000 

SP8000 

SP10000 

SP12000 

SP15000 

Zulauf 

Ø 32 / Ø 38 

[mm] 

Ø 32 / Ø 38 

[mm] 

Ø 38 [mm] 

Ø 38 [mm] 

Ø 38 [mm] 

Ø 38 [mm] 

Ablauf 

Ø 32 / Ø 38 

[mm] 

Ø 32 / Ø 38 

[mm] 

Ø 38 [mm] 

Ø 38 [mm] 

Ø 38 [mm] 

Ø 38 [mm] 

Stromaufnahme 

0.35 [hp] 

250 [W] 

0,5 [hp] 

400 [W] 

0,65 [hp] 

450 [W] 

1,2 [hp] 

900 [W] 

1,2 [hp] 

900 [W] 

1,3 [hp] 

1000 [W] 

Max. Leistung 

100 [l/min] 

130 [l/min] 

160 [l/min] 

210 [l/min] 

230 [l/min] 

250 [l/min] 

Max.Förderhöhe 

7 [m] 

7,0 [m] 

9 [m] 

14 [m] 

12,5 [m] 

15 [m] 

Gewicht 

6 [kg] 

8 [kg] 

8 [kg] 

10 [kg] 

10 [kg] 

10 [kg] 

Schutzklasse 

IPX4 

IPX4 

IPX4 

IPX4 

IPX4 

IPX4 

Max. Wassertemperatur 

35[°C] 

35[°C] 

35[°C] 

35[°C] 

35[°C] 

35[°C] 

 

Wasser Höchsttemperatur: 35[°C] 

 

 

 

Wasser Mindesttemperatur: 4[°C] 

Akustischer Druck: <70 [dB(A)] 

 

ANWEISUNGEN UND SICHERHEITSNORMEN 
 

Heben  Sie  diese  Anleitung  für  späteres  Nachschlagen  auf,  wenn  möglich,  an  einem  sicheren  und  trockenen  Ort,  in 

Pumpennähe. Diese Anleitung beinhaltet die Grundanweisungen, die man während der Installation, des Betriebes und 

der Instandhaltung befolgen muss, deswegen muss sie vor der Pumpennutzung gründlich gelesen werden. 

 

Die Pumpe wurde entworfen und realisiert, um in Süßwasser Haushaltspools zu arbeiten. 

Die Pumpe nicht in Wasser tauchen. 

 

Vergewissern Sie sich, dass die Elektrikanlage  gemäß den gültigen internationalen Richtlinien ist. 
Vergewissern Sie sich, dass das Produkt mit den Charakteristiken Ihrer Elektroanlage kompatibel ist. 

Die  Pumpe  muss  durch  einen  differentialen  Sensibilitätsschalter  von  nicht  mehr  als  30    [mA]  an  der  Elektroanlage 

angeschlossen  werden.  Der  Differentialschalter  muss  omnipolar  sein  und  die  Öffnungsentfernung  der  Kontakte  darf 
nicht weniger als 3 [mm] sein. 

Ziehen  Sie  niemals  an  dem  Elektrokabel.  Sollte  das  Kabel  beschädigt  werden,  wenden  Sie  sich  an  einen 

Spezialtechniker. 

 

Bevor Sie an der Pumpe eingreifen, trennen Sie sie von der Stromanlage. 

Die Pumpe darf nicht in Betrieb genommen werden, wenn sich Personen im Pool befinden. 

Entfernen Sie niemals, auf keinen Fall, den Schütz-Carter des Kühlgebläses. 

 

 

ACHTUNG: Ziehen Sie den Pumpenstecker raus, bevor Sie jeglichen Eingriff vornehmen. 

 

 

Die Sicherheit der Maschine ist nur dann gewährleistet, wenn sie nach den Richtlinien dieser Anleitung benutzt wird. Die 
längere  Aufbewahrung  in  Räumen  mit  hoher  Feuchtigkeit  und/oder  variablen  Temperaturen,  muss  vermieden  werden. 

Feuchtigkeit und Kondenswasser können die Pumpenkomponenten beschädigen. 

 

POSITIONIERUNG 

 

Summary of Contents for SP10000

Page 1: ...ISTRUZIONI INSTRUCTIONS INSTRUCTIONS INSTRUCTIONS ANLEITUNGEN Serie SP...

Page 2: ...ere letto attentamente prima di utilizzare la pompa La pompa stata progettata e realizzata per lavorare in piscine domestiche di acqua dolce Non immergere la pompa in acqua Verificate che l impianto e...

Page 3: ...Utilizzare un apposito riduttore per collegare la spina alla rete nel caso fosse necessario In caso di rottura del cavo rivolgersi a personale qualificato per la sostituzione non sostituire personalme...

Page 4: ...E Se la pompa si blocca necessario un intervento di pulizia Il ripetuto tentativo di avviare una pompa bloccata causa danni irreparabili In questo caso la garanzia perde validit ATTENZIONE Tutti i lav...

Page 5: ...i Garanzia applicabile unicamente nei paesi dell Unione Europea 2 3 Per la validit di questa garanzia l acquirente dovr attenersi strettamente alle indicazioni del Fabbricante incluse nella documentaz...

Page 6: ...tallation operating and maintenance It must therefore be carefully read before using the pump The pump has been designed and realized to run in freshwater domestic pools Do not submerge the pump in wa...

Page 7: ...ain the triggering time when the pump is started up again for example after cleaning the frame The plug must always be easily reachable ELECTRICAL CONNECTION The pump is outfitted with a 5 m waterproo...

Page 8: ...the pump will begin to run again If the thermal breaker should be triggered again frequently have the pump checked by qualified personnel and make sure also the domestic electric network is inspected...

Page 9: ...the products which this manual refers to 2 2 The present Certificate of Guarantee is to be applied only in the European Union s countries 2 3 In order this guarantee to be valid the buyer will have t...

Page 10: ...er la pompe La pompe a t con ue et r alis e pour fonctionner dans des piscines d eau douce usage domestique Ne pas plonger la pompe dans l eau V rifier que l installation lectrique soit conforme aux n...

Page 11: ...n c ble de 5 m r sistant l eau et d une prise Schuko tripolaire Ne pas alt rer cette configuration sans l autorisation d un technicien sp cialis Utiliser un r ducteur sp cifique pour brancher la prise...

Page 12: ...gne lectrique usage domestique ATTENTION Si la pompe se bloque il est n cessaire d effectuer une intervention de nettoyage Les essais de remise en route r p t s d une pompe bloqu e peuvent causer des...

Page 13: ...Garantie est valable uniquement dans les pays de l Union Europ enne 2 3 Afin que cette Garantie soit valide l acheteur devra strictement s en tenir aux indications du Fabricant incluses dans les docu...

Page 14: ...ci n el funcionamiento y el mantenimiento de la bomba por lo tanto debe ser leido atentamente antes de utilizar la misma La bomba ha sido dise ada y realizada para trabajar en piscinas dom sticas de a...

Page 15: ...ejemplo despu s de la limpieza del cesto instalcci n hecha hay que poder acercarse al enchufe CONEXI N EL CTRICA La bomba est dotada de un cable de 5 m resistente al agua y de enchufe de tres polos Sc...

Page 16: ...onal calificado y asegurarse de que sea inspeccionada tambi n la red el ctrica dom stica ATENCI N si se bloqueara la bomba ser necesaria una intervenci n de limpieza El reiterado tentativo de puesta e...

Page 17: ...El presente Certificado de Garant a ser de aplicaci n nicamente en los pa ses de la Uni n Europea 2 3 Para la eficacia de esta garant a el comprador deber seguir estrictamente las indicaciones del Fab...

Page 18: ...olgen muss deswegen muss sie vor der Pumpennutzung gr ndlich gelesen werden Die Pumpe wurde entworfen und realisiert um in S wasser Haushaltspools zu arbeiten Die Pumpe nicht in Wasser tauchen Vergewi...

Page 19: ...hrung darf ohne Genehmigung eines Fachmanns nicht ge ndert werden Zum Anstecken wenn notwendig einen zweckm igen Reduzierer benutzen Bei Besch digung des Kabels sich an qualifiziertes Personal wenden...

Page 20: ...mpe blockiert muss sie gereinigt werden Bei wiederholtem Blockieren sollte man nicht versuchen die Pumpe wieder einzuschalten es k nnten unbehebbare Sch den verursacht werden In diesem Fall w rden auc...

Page 21: ...hrten Garantieleistungen erstrecken sich auf die in diesem Handbuch beschriebenen Produkte 2 2 Dieser Garantieschein hat nur in den EG Staaten G ltigkeit 2 3 Die Garantie ist g ltig wenn der K ufer d...

Page 22: ...itigen Diese Ger t an eine daf r vorgesehene Sammelstelle bringen gem den vorortigen und auf nationalem Gebiet geltenden Gesetzesbestimmungen Der Verbraucher kann betr chtlich dazu beitragen den Abfal...

Page 23: ...ue pr filtre 9 Guarnizione Garnitture 10 Diffusore Diffuseur 11 Corpo Motore Motor body Motork rper Cuerpo Motor Corps moteur 12 Viti Prefiltro Pre filter screws Schrauben f Vorfilter Tornillos Prefil...

Page 24: ...i n del artefacto modelo Ger ts Modellsbeschreibung Pump SP4000 SP6000 SP8000 SP10000 SP12000 SP15000 Direttive UE EU directives Directive UE Directivas UE EU Vorschrift Direttiva UE Macchine 89 392 C...