APPLICATION:
Series SP pool pumps have been designed to move clean fresh water exclusively for private use.
The manufacturer is not responsible if the pumps are used for purposes other than those indicated above
without explicit authorization.
TECHNICAL FEATURES:
Technical features
230V - 50Hz
SP4000
SP6000
SP8000
SP10000
SP12000
SP15000
Inlet
Ø 32 / Ø 38
[mm]
Ø 32 / Ø 38
[mm]
Ø 38 [mm]
Ø 38 [mm]
Ø 38 [mm]
Ø 38 [mm]
Outlet
Ø 32 / Ø 38
[mm]
Ø 32 / Ø 38
[mm]
Ø 38 [mm]
Ø 38 [mm]
Ø 38 [mm]
Ø 38 [mm]
Power
0.35 [hp]
250 [W]
0,5 [hp]
400 [W]
0,65 [hp]
450 [W]
1,2 [hp]
900 [W]
1,2 [hp]
900 [W]
1,3 [hp]
1000 [W]
Max capacity
100 [l/min]
130 [l/min]
160 [l/min]
210 [l/min]
230 [l/min]
250 [l/min]
Max head
7 [m]
7,0 [m]
9 [m]
14 [m]
12,5 [m]
15 [m]
Weight
6 [kg]
8 [kg]
8 [kg]
10 [kg]
10 [kg]
10 [kg]
Protection grade
IPX4
IPX4
IPX4
IPX4
IPX4
IPX4
Max water temperature
35[°C]
35[°C]
35[°C]
35[°C]
35[°C]
35[°C]
Maximum water temperature: 35[°C]
Minimum water temperature: 4[°C]
Acoustic pressure: <70 [dB(A)]
RECOMMENDATIONS AND SAFETY RULES
Preserve this manual for future reference, if possible in a safe and dry place, near the pump. This manual contains
basic instructions that must be followed during installation, operating and maintenance. It must therefore be carefully
read before using the pump.
The pump has been designed and realized to run in freshwater domestic pools.
Do not submerge the pump in water.
Make sure the electric plant complies with international prescriptions in force.
Make sure the product is compatible with the characteristics of your electric plant.
The pump must be connected to the electric supply with a differential switch having sensitivity not above 30 [mA].
The differential switch must be omnipolar and the minimum separation between the contacts must not be less than 3
[mm].
Never pull the electrical cable. If the cable is damaged apply to a specialized technician.
Before carrying out operations on the pump, disconnect it from the electric network.
The pump must never be turned on when there are people inside the pool.
Never remove, for any reason, the safety casing from the cooling fan.
ATTENTION: Disconnect the pump from the electric network before carrying out any operations.
Safety of the machine is guaranteed only if used in compliance with what is provided for in this manual. Avoid leaving it in
places that have high humidity and/or variable temperatures for long periods of time. Humidity and condensate may
damage the pump components.