61(65)
When carrying out maintenance, ensure that there is no material left in the
granulator.
Caution!
All repairimg must be conducted by professionals to avoid personal
injuries and machine damages!
6.3.1 Daily Check
1) There is rubber shutter in the feed box. If the rubber shutter is damaged,
replace it immediately. Otherwise the fragment of the shutter will damage the
blades in the cutting chamber.
2) Check whether the Emergency Stop works properly. Start the machine and
then stop it via Emergency Stop. Rotate the button anti-clockwise to reset
the Emergency Stop.
3) Check the main power switch, start/stop button.
4) Check the reversed rotating function.
5) Check star screw, safety screw is part of granulator
’
safety system, its length
is pre-designed, when the screw is loosen, the granulator will stop working
so to protect the machine. The thread length of the safety screw is 60mm,
damaged screw needs to be replaced by a new one.
Picture 6-4: Star Screws
6.3.2 Weekly Check
Summary of Contents for SG-24T
Page 1: ...SG 24T Screenless Granulator Date Apr 2013 Version Ver B English...
Page 2: ......
Page 8: ...8 65...
Page 25: ...25 65 2 3 3 Cutting Chamber and Blade Rest Picture 2 5 Cutting Chamber and Blade Rest...
Page 29: ...29 65 2 4 Electrical Diagram 2 4 1 Main Circuit 400V Picture 2 9 Main Circuit 400V...
Page 30: ...30 65 2 4 2 Control Circuit 400V Picture 2 10 Control Circuit 400V...
Page 31: ...31 65 2 4 3 Electrical Components Layout 400V Picture 2 11 Electrical Components Layout 400V...
Page 34: ...34 65 2 4 5 Main Circuit 230V Picture 2 12 Main Circuit 230V...
Page 35: ...35 65 2 4 6 Control Circuit 230V Picture 2 13 Control Circuit 230V...
Page 36: ...36 65 2 4 7 Electrical Components Layout 230V Picture 2 14 Electrical Components Layout 230V...
Page 40: ...40 65 2 5 4 Proportional Valves Picture 2 18 Control Cabinet and Valve...