Warranty

LIMITED EXPRESS WARRANTY

Shimpo Instruments warrants, to the original purchaser of new products only, that this product shall be free from defects in workmanship and
materials under normal use and proper maintenance for one year from the date of original purchase.  This warranty shall not be effective if
the product has been subject to overload, misuse, negligence, or accident, or if the product has been repaired or altered outside of Shimpo
Instruments’s authorized control in any respect which in Shimpo Instruments’s judgment, adversely affects its condition or operation.

DISCLAIMER OF ALL OTHER WARRANTIES

The foregoing warranty constitutes the SOLE AND EXCLUSIVE WARRANTY, and Shimpo Instruments hereby disclaims all other warranties,
expressed, statutory or implied, applicable to the product, including, but not limited to all implied warranties of merchantability and fitness.

LIMITATION OF REMEDY

Under this warranty, Shimpo Instruments’ SOLE OBLIGATION SHALL BE TO REPAIR OR REPLACE the defective product or part, at Shimpo
Instruments’ option.  Shimpo Instruments reserves the right to satisfy warranty obligation in full by reimbursing Buyer for all payments made to
Shimpo Instruments, whereupon, title shall pass to Shimpo Instruments upon acceptance of return goods.  To obtain warranty service, Purchaser
must obtain Shimpo Instruments’s authorization before returning the product, properly repackaged, freight pre-paid to Shimpo Instruments.

INDEMNIFICATION & LIMITATION OF DAMAGES

Buyer agrees to indemnify and hold Shimpo Instruments harmless from and against all claims and damages imposed upon or incurred
arising, directly or indirectly, from Buyer’s failure to perform or satisfy any of the terms described herein.  In no event shall Shimpo Instruments
be liable for injuries of any nature involving the product, including incidental or consequential damages to person or property, any economic
loss or loss of use.

MERGER CLAUSE

Any statements made by the Seller’s representative do not constitute warranties except to the extent that they also appear in writing.  This
writing constitutes the entire and final expression of the parties’ agreement.

Troubleshooting

The following are general checkpoints; please call your local Shimpo representative or contact Shimpo Instruments

directly for further assistance.

If display is blank:

Check all connections: power source (AC type: 85-264VAC 50/60Hz; DC type: 9-35VDC), power cord and wires

(

NOTE

: For DC applications confirm that correct voltage polarity is used)

Error codes are displayed:

Turn power OFF and then ON

If error code remains, see table below

DISPLAY

CONDITION

ACTION

Change parameter 
settings or input 
signal

Change the input 
signal width

Decrease the input 
RPM

Press SET key

Input signal width is under 
10 msec in MODE 3

Beyond the limit of TEA 
function

EE PROM reading error

Overflow of display (when 
display value is over the 
limit of display)

Copyright

©

 Nidec-Shimpo America Corporation 2000.  All rights reserved.  Product specifications are subject to change without notice

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for DT-5TS

Page 1: ...Instruction Manual DT 5TXR DT 5TS DIGITAL PANEL MOUNT TACHOMETER www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...rtant Safety Precautions 3 Display and Keypad 4 Rear Panel and Terminals 5 Set Up 5 Power 5 Sensor Connection 5 Self Test 5 Panel Installation 6 Factory Settings 6 Parameter Settings 6 Function Settin...

Page 3: ...g while saving time Accepts modules DT 5TXR only which provide different types of outputs i e analog voltage analog current 4 20 mA relay closures set points BCD output and others for recording purpos...

Page 4: ...a r a p s t e S n o t t u B t e S 7 n o i t c e l e s e d o M n o t t u B e d o M 8 l a c e d r o f a e r A l a c e D t i n U 9 t n e m e r u s a e m f o s t i n u s y a l p s i D y a l p s i D y r a...

Page 5: ...nts etc 4 When satisfied that all LED s are operational press the SET button to exit SENSOR TYPE TERMINAL NUMBER FREQUENCY or RPMRANGE OPERATION TEMPERATURE FILTER M P R 0 0 0 5 0 C 0 6 B 1 E R 3 0 C...

Page 6: ...1 000 RPM 3 Display units 1000 1 000 4 Update time _ 1 0 _ 1 second 5 Display Hold after input signal ceases _ _006 0 6 seconds 6 Input filter _ 10 _ 10 kHz DEFAULT FACTORY SETTING PARAMETER DESCRIPT...

Page 7: ...ogrammed into the DT 5TXR DT 5TS In addition there are also function settings to further customize the DT 5TXR DT 5TS NOTE Because the flow rate measurement mode 04 is only used in the Japanese market...

Page 8: ...feet per minute and the belt that is being measured is moving at a rate of 55 5 f min then 5 5 5 would have to be entered and the negative decimal point button pressed once If the desired reading is R...

Page 9: ...Press the PAR button 8 Use any of the lower buttons to scroll through see table above and select an update time 9 Press the PAR button 10 Use the NUMERIC buttons to enter the time in seconds that the...

Page 10: ...e meter will then use this number to set parameters 1 and 2 Set the teaching feature as follows 1 Determine the output RPM 2 Confirm that the meter is receiving a signal from the sensor the SIG indica...

Page 11: ...e r e t s y H 2 _ __ _ 0 0 0 3 Secures the 1st high and 1st low setting 0 not secured 1 secured _ 0 _ Notsecured d n o c e s 9 9 0 t i m i l t e s y n a f o n o i t a v i t c a t u p t u O 4 _ __ _ 0...

Page 12: ...activate the MEM button by pushing it momentarily The lower left secondary display will reflect the maximum value of the main display and the lower right secondary display will reflect the minimum val...

Page 13: ...nd the operator wants to observe the changes in this case higher update times are selected or if the speed changes rapidly within certain limits this may bother the observer a lower update time is sel...

Page 14: ...DT 5TS has a MODE for this application and similar ones where it can measure the ON time of a signal that starts when the process begins until it ends see signal waveform diagram top right NOTE The di...

Page 15: ...20mA DOP CPTR Relay output HI GO LO 3 C type relays DOP TRTR NPN OC output H 1 H 2 GO L 1 L 2 and ZERO DOP RMTR Ratio of two input functions Lower Connector Options with Connectors C DOP FVC Analog ou...

Page 16: ...OP FVC module coupled with the DT 5TXR panel meter provides three popular voltage outputs and one current output for recording purposes and PLC applications The voltages are a 0 to 10 VDC b 1 to 5 VDC...

Page 17: ...ll be approximately 10 msec 1 indicates that the update time will correspond with the display update time already chosen see Setting Mode Parameters 4 7 Press the FUN button display will reflect The d...

Page 18: ...Module DT 5TXR BCD The model DT 5TXR BCD combination satisfies PCs and PLCs that require a BCD parallel signal The DOP BCD module can be configured with a negative logic output 0 HI and 1 LO or a posi...

Page 19: ...ncy 30 kHz 0 999999 with selectabledecimal point 0 008 1 digit DT 5TXR Display Range MODEL Mode r e t e M e t a R r e t e m o h c a T Elapsed Time Process Time 0 00 00 9 59 59 0 00 00 0 59 59 or or 0...

Page 20: ...NIFICATION LIMITATION OF DAMAGES Buyer agrees to indemnify and hold Shimpo Instruments harmless from and against all claims and damages imposed upon or incurred arising directly or indirectly from Buy...

Reviews: