6
Factory Settings
The following charts reflect the default parameter and function settings as programmed by the factory:
Operating Mode -01- (RPM or Rate Measurement)
Panel Installation
Install the DT-5TXR/DT-5TS on panel as follows:
1. Confirm that the panel thickness is 0.047” - 0.197” (1.2 mm - 5 mm).
2. Remove the two mounting adapters (provided) from the DT-5TXR/DT-5TS (diagram 2).
3. Install a water-resistant gasket on the panel (see diagram 3 & 4).
4. Hold the panel meter in a horizontal position, insert it into the cut-out and press against gasket (diagram 5).
5. Replace the two mounting adapters (diagram 6).
6. The DT-5TXR/DT-5TS is secured on the panel by using the two mounting screws (provided) (see diagram 7).
3
m
a
r
g
a
i
d
2
m
a
r
g
a
i
d
7
m
a
r
g
a
i
d
6
m
a
r
g
a
i
d
5
m
a
r
g
a
i
d
diagram 4
DISPLAY
1
Pulses per revolution
_ _
0001
1 ppr
2
Sensing RPM
_
01000
1,000 RPM
3
Display units
1000
1,000
4
Update time
_
1.0
_
1 second
5
Display “Hold” after input signal ceases
_ _
006.0
6 seconds
6
Input filter
_
10
_
10 kHz
DEFAULT FACTORY SETTING
PARAMETER
DESCRIPTION
DISPLAY
MEANING
1
The 2nd HI and 2nd LO limit setting
0 0 0 0 0 0
0
2
Hysteresis of 1st HI and 1st LO set
_ _ _ _
0 0
0
3
Secures the 1st HI and 1st LO set
_
0
_
Not secured
4
Output activation of any set limit
_ _ _ _
0 0
0 seconds
5
Selection of secondary display
_
0
_
1st HI and 1st LO limit set
6
Main display shows 0 below this no. setting 0 0 0 0 0 0
0
7
Averages the sensor output frequency
_
0
_
None
8
Deceleration to ZERO display value
_
0
_
Off
10
Logic of BCD output
_
0
_
Negative-true logic
11
Analog output value
0 0 1 0 0 0.
1000
12
Minimum value of analog output
0 0 0 0 1 0.
10
13
Update time for analog output
_
0
_
About 10 msec
14
Offset for analog output
_
0 0 0.0
0%
DEFAULT FACTORY SETTING