Parameter Description
Parameters
167
If both P.288 and P.290 are 0, P.289 and P.291 will be displayed as 0.
Abnormal code corresponded alarm condition:
Abnormal
code
Alarm
type
Abnormal
code
Alarm
type
Abnormal
code
Alarm
type
Abnormal
code
Alarm
type
Abnormal
code
Alarm
type
00
No
alarm
32
OV1
49
THN
82
IPF
144
OHT
16
OC1
33
OV2
50
NTC
97
OLS
160
OPT
17
OC2
34
OV3
64
EEP
98
OL2
179
SCP
18
OC3
35
OV0
65
FAN
112
BE
192
CPU
19
OC0
48
THT
66
PID
129
AEr
193
CPR
209
PG1
210
PG2
211
PG3
5.7
5
Accumulative Motor Operation Time Function (P.292 and P.293)
P.292 “Accumulative motor operation time (minutes)”
P.293 “Accumulative motor operation time (days)”
Parameter
Factory setting
Setting range
Remarks
292
0 min
0~1439min
---
293
0 day
0~9999day
---
<Setting>
• P.292 is about the accumulative motor operation time in minutes. The updated value cannot
be modified by executing P.998 or power shutdown. To clear the accumulated time, make
P.292=0.
• P.293 is about the accumulative motor operation time in days. The updated value cannot be
modified by executing P.998 or power shutdown. To clear the accumulated time, make
P.293=0.
5.7
6
Password Protection Function (P.294 and P.295)
P.294 “Decryption parameter”
P.295 “Password setup”
Parameter
Factory setting
Setting range
Remarks
294
0
0~65535
---
295
0
2~65535
---