Appendix 1 Parameter Table
Parameter Table
208
Parameter
Number
Name
Setting Range
Minimum
Setting
Unit
Default Value
User
Setting
Value
Reference
Page
S pattern time at the end of
Deceleration
0~25s/0~250s,
99999
0.01s/0.1s
99999
P69
Speed unit selection
0, 1
1
1
P95
Over torque detection selection
0, 1
1
1
P134
Maintenance Alarm Time
0~9998 day
1
0
P162
Regeneration avoidance operation
selection
0,1,2,11,12
1
0
P16
3
Regeneration and avoidance DC
bus voltage level
300~800
1
760
P16
3
Regeneration and avoidance
detection sensitivity at deceleration
1~5
1
0
P16
3
Regeneration and avoidance
frequency compensation limit value
0~10.00HZ
0.01HZ
6.00HZ
P16
3
Regeneration and avoidance action
accommodation coefficient 1
0~200.0/20.00
0.1/0.01
100.0/10.00
P16
3
Regeneration and avoidance action
accommodation coefficient 2
0~200.0/20.00
0.1/0.01
100.0/10.00
P16
3
Input Phase Failure Protection
0
,
1
1
0
P165
Low frequency vibration inhibition
factor
0~3
1
1
P165
High frequency vibration inhibition
factor
0~15
1
0
P165
Short circuit protection (SCP)
function selection
0~1
1
1
P166
Alarm code display option
0~12
1
0
P166
Alarm code
---
---
0
P166
The latest alarm status selection
0~7
1
0
P166
The latest alarm message
---
---
0
P166
Accumulative motor operation time
(minutes)
0~1439min
1min
0
P167