Parameter Description
Parameters
154
5.6
2
1-5 Terminal Input Signal (P.506
,
P.514~P.521)
P.506 “The bias rate of 1-5 voltage
signal”
P.514 “The setting corresponding to
the minimum positive voltage of
terminal 1-5”
P.515 “The setting corresponding to
the maximum positive voltage of
terminal 1-5”
P.516 “The minimum input positive
voltage of terminal 1-5”
P.517 “The maximum input positive
voltage of terminal 1-5”
P.518 “The setting corresponding to
the minimum negative voltage of
terminal 1-5”
P.519 “The setting corresponding to
the maximum negative voltage of
terminal 1-5”
P.520 “The minimum input negative
voltage of terminal 1-5”
P.521 “The maximum input negative
voltage of terminal 1-5”
Related parameters
P.530
“
The selection of voltage
signal across terminal 1-5
”
P. 80~P. 84 , P. 86
“
Multi-function terminals selection
”
P.509
“
The maximum operation
frequency of terminal 1-5
”
P.502
“
Function selection of terminal 1-5
”
Parameter
Factory
tti
Setting range
Remarks
506
0%
-100%~100%
Refer to P.139
514
0%
-100%~100%
Refer to P.194
515
100%
-100%~100%
Refer to P.195
516
0
0~10V
Refer to P.192
517
5V
0~10V
Refer to P.193
518
0%
-100%~100%
Refer to P.510
519
0%
-100%~100%
Refer to P.511
520
0
0~10V
Refer to P.512
521
0
0~10V
Refer to P.513
<Setting>
•
The setting of 1-5 terminal input voltage is similar to the setting of 2-5. And they also have
the same effect.
Note: The selection of range of voltage signal sampling across terminal 1-5 by parameter P.530 will affect
the parameters value of 1-5 terminal input signal in this part.