4-8
VL-E610S/VL-E610H
VL-E660S/VL-E96E
VL-E98E
4-4. ADJUSTMENT OF MECHANISM TAPE TRAVEL SYSTEM
4-4-1. Preparation for adjustment
(1) Clean the tape running areas (guide poles, rollers, drum, Capstan shaft, Pinch roller) (Figure 1)
(2) Connect the oscilloscope to the following TPs.
RF output ... TL3306
H-SW-P ...... TL405
GND ........... TL3318
(3) Playback the alignment tape (VR2DBOPS).
(4) Ascertain that each guide is free from remarkable curl.
(5) Ascertain that the RF waveform of inlet and outlet sides is flat on the oscilloscope (Figure 2, (a)). Unless the waveform
is flat, (Figure 2, (b), (c)), make an adjustment as follows.
4-4-2. Adjusting the Sup GR and Tu GR
(1) Turn the Sup and Tu guide rollers to get the flat waveform at the inlet and outlet sides.
Tape travel system (Figure 1)
,,,
,,,
,,,
,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
,,,,,,
Drum
Reel
Tension pole
Si roller
Sup GR
Sup tilted pole
Tu tilted pole A
Tu GR
Tu tilted pole B
Capstan shaft
Tu guide
Pinch roller
Figure 2
Inlet side
Outlet side
(a) Normal
(b) Inlet side
waveform is disturbed.
(c) Outlet side
waveform is disturbed.