5. Disassembly of the LCD holder
(1)Remove two screws ((d)XiPSF20P04000), pull out the tripod angle.
(2)Remove the remote control ray reception PWB from the LCD, (Distorting the claw (snap-fit type) of the LCD holder,
release its engagement.)
Claw
Remote control ray reception PWB
(3)Remove two screws ((b)LX-HZ0018TAFF) and two connectors, and remove the LCD unit (with inverter) from the main
body.
Remote control ray reception section
Tripod angle
(d)
Claw
(b)
LCD unit
(4)Disconnect the connector which connects the Li/RC unit to the main PWB, and slide the Li/RC unit in the arrow direction
from the frame V.
Note:
When connecting the FPC, pass it through the inside of rib of frame V (to prevent the FPC from being jammed).
Inverter transformer
Main PWB
Connector
Li/RC unit
Connector