3-3-2. REMOVAL OF CCD
1) Unsolder the CCD sensor leads from the sensor PWB.
2) Take out the sensor PWB.
3) Remove the two screws (6), and remove the sensor holder and CCD sensor.
3-3-3. MOUNTING OF CCD
1) Place the lens unit upright (since the CCD sensor mount ID faces upward, care must be taken so as not to damage the
front lens of unit), put the crystal filter first and then the dust protection rubber into the CCD holder of lens unit. Set the
crystal unit with its thin side toward the lens unit.
2) Place the CCD sensor so that the its No. 1 pin is at the right lower (Positioning hole to be at right), and put the CCD sensor
into the CCD holder. For smooth and tight fitting, press the right lower part of back of CCD sensor, and then press the
left upper part.
Note: Pay attention to the direction of CCD sensor.
3) Place the sensor holder so that its two round markings be visible, and fix the sensor holder with the two screws ((6)LX-
HZ0013TAFF).
4) Mount the sensor PWB so that the CCD sensor leads go thorough the PWB holes.
5) Solder the CCD sensor lead to the sensor PWB.
Note: Take care not to apply excessive heat.
3-9
Rubber
Lens
Side
CCD
Side
The THIN SIDE
faces the lens
Crystal
CCD Sensor
Sensor Holder
(6)
Mark
The mark must be on
this face.
3-3. REPLACEMENT OF CCD SENSOR
3-3-1. BEFORE REPLACEMENT
1) The CCD image sensor is more sensitive to electrostatic breakage than C-MOS LSI. Therefore sufficient means to
prevent electrostatic damage must be taken when it is replaced.
•
Ground the soldering iron.
•
Ground also the human body, using the wrist strap(through an 1 Mohm resistor).
•
Until the CCDsensor is mounted on the PWB, fit it to the conductive sponge, and short-circuit the foot lead.
2) Take utmost care so that the surface glass of CCD sensor and optical filter are not contaminated and damaged. If any
contamination is found, for example fingerprint, wipe it off with silicon paper or clean chamois skin.
3) When replacing the CCD sensor, use the antistaic grounded soldring iron, and perform quickly soldering.
V-OFD voltage marked on the back of CCD
Note:
Indication of voltage (ofd) set value.
Voltage set value is indicated on the back of the CCD sensor.
JAPAN
SHARP
Index Mark
LZ2423H5
YYWWXXX
1
7
14
8