Fusing temperature adjustment after 20 sheets of continuous printing
Test command (Simulation)
MODE
Normal
MAIN CODE
43
SUB CODE
4
∗
Execution time
Enforcement
time
JOB No
Content
S 009/Ua 002
When replacing MCU PWB
In case of U2 trouble
Cycle
—
Condition
—
∗
Job content
(Fusing temperature adjustment within 20 sheets of continuous print-
ing)
1) Enter SIM 43-1 mode.
(The currently set code of the fusing temperature adjustment
within 20 sheets of continuous printing is displayed.)
2) Set the adjustment value to 0 (160°C) and press the start button.
(Fusing temperature adjustment after 20 sheets of
continuous printing)
1) Enter SIM 43-4 mode.
(The currently set code of the fusing temperature adjustment after
20 sheets of continuous printing is displayed.)
2) Set the adjustment value to 1 (155°C) and press the start button.
∗
Trouble caused by improper work
1) Fusing abnormality
2) Fusing section parts damage
3) Paper jam
∗
Note
Be sure to set to the standard value. If not a trouble may occur.
ADJ M8
Power voltage adjustment
∗
Location
∗
Adjustment value
Range (MIN)
23.5V
Range (MAX)
24.5V
Standard value
24V
∗
Execution time
Enforcement
time
JOB No
Content
S 009/Ua 001
When replacing a power in the
PWB unit.
∗
Necessary condition
1) Adjust with the AC power voltage in the specified range (90
∼
110% of the standard power voltage).
∗
Job content
1) Manually turn on the cabinet switch.
2) Turn on the power.
3) Put a digital multi-meter between the check point (24V) on the
power PWB and GND.
4) Turn the adjustment volume (VR601) on the power PWB and
adjust the 24V output to 24
±
0.5V.
∗
Trouble caused by improper job
1) Circuit malfunction
2) Circuit parts damage
∗
Necessary tool
Name
Digital multi-meter
Parts code/Price rank
—
ADJ M9
Copy lamp light quantity adjustment
∗
Location value
Range (MIN)
3.9 V
Range (MAX)
4.1 V
Standard value
4.0 V
Default
4.0 V
∗
Program used
Test command (Simulation)
MODE
Normal
MAIN CODE
63
SUB CODE
1
∗
Enforcement time
Enforcement
time
JOB No
Content
S 004/Ua 001/
P 002
When replacing the scanner
(copy) lamp control PWB
When replacing the copy lamp
In case of E7 (05) trouble
In case of E7 (04) trouble
In case of E7 (12) trouble
In case of E7 (15) trouble
Cycle
—
Condition
Normal copy exposure is not
obtained.
ADJ M8(VR601)
CPWBF7045XC35
F9225PA
B075
FO-3800M
7 – 19