(6) Dial test / adjustment mode (Pulse 10PPS)
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗
, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION = <version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←
→
)
3
Press 1, 4.
14:DIAL TEST 10 PPS
MAKE RATIO = ##%
The current make ratio setup is displayed on ##.
4
Press
←
or
→
.
(If there is no need to adjust, no need to press.)
14:DIAL TEST 10 PPS
MAKE RATIO = ##%
Press
←
to decrease by 1%.
Press
→
to increase by 1%.
5
Press ENTER.
“1590” is dialed.
6
(Adjustment/test end)
Press STOP.
This mode is terminated.
(To continue adjustment/test)
Return to 4.
(7) Dial test mode (Tone)
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗
, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←
→
)
3
Press 1, 6.
16:DIAL TEST TONE
“123456789
∗
0#” is dialed.
This mode is terminated.
(8) Print out soft switch mode
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗
, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←
→
)
3
Press 2, 1.
21:PRINT SOFT SW
The soft switch list is printed.
This mode is terminated.
(9) Panel check mode
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗
, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←
→
)
3
Press 4, 2.
42:FAX PANEL TEST
4
Press any key.
42:FAX PANEL TEST
<key name>
The name of the pressed key is displayed in
the lower stage of the LCD.
5
Press STOP.
This mode is terminated.
(10) Signal detect mode
Procedure
LCD
Operation
1
Press FUNCTION, 9,
∗
, 8, #, 7.
DIAGNOSTIC MODE
ROM VERSION =
<version>
2
Press ENTER.
DIAGNOSTIC MODE
SELECT MENU(
←
→
)
3
Press 4, 3.
43:SIG. DETECT
4
(When DTMF signal is detected)
43:SIG. DETECT
DTMF:<number>
(When CNG signal is detected)
43:SIG. DETECT
CNG
(When QUIET signal is detected)
43:SIG. DETECT
QUIET
(To terminate this mode)
Press STOP.
This mode is terminated.
FO-3800M