(11) Adjustment volume
No.
Parts
Note
Code
Name
Function/operation
1
VR1
Scanner lamp light quantity adjustment
volume
Adjusts the scanner lamp light quantity.
2
VR601
Output voltage adjustment volume
Adjust the DC output voltage (
+
24V).
3
VR801
Main charger voltage adjustment volume
Adjusts the main charger voltage.
4
VR802
Developing bias voltage adjustment
volume
Adjusts the developing bias voltage.
D. Lock position
No.
Parts
Note
Name
Function/Operation
1
Scanner lock screw
Locks the scanner unit.
Fixes the scanner unit with this screw when in transit.
1)
VR601
VR802
VR801