SW
NO.
Data
NO.
Item
Switch selection and contents of functions
Initial value
User
program
No.
Remark
SW2
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Remote select
No. setup
Used to set the number for remote select reception from
an external telephone with binary input. However, the
remote select numbers “x
∗
” and “
∗
” are fixed.
For an input over “10”, the same operation as the initial
value of “5” is performed.
5
0
108
When a value
in the range of
10 – 15 is set,
set to “5.”
6
1
7
0
8
1
SW3
1
Density default
setup
Used to set the density (LED) after pressing C/A key or
in auto clear operation to Auto, Light, Slightly light,
Medium, Slightly data, and Dark.
Auto
153
2
0
3
0
4
0
5
0
6
Reserved
0
7
Size
specification
Used to set the source of judgement of size specification
(AB series or inch series).
Follows
the
machine
informa-
tion.
∗
8
1
SW4
1
Recall interval
in case of a
communication
error
Used to set recall interval after disconnection of
communication due to a communication error in memory
transmission. The set range is 0 to 15 min in the
increment of 1 min by binary input. When set to 0, recall
is made immediately after disconnection. However, the
time interval set by SW21 (Interval between the end of a
communication and the next call) is taken.
1 min
0
113
2
0
3
0
4
1
5
Recall interval
in case of
busy state
Used to set recall interval after disconnection of
communication due to the busy state of the other party
or no response. The set range is 0 to 15 min in the
increment of 1 min by binary input. When set to 0, recall
is made after 3 min.
3 min
0
111
When “0000” is
tried to be set,
“0011” is set.
6
0
7
1
8
1
SW2 Bit No.
1 2 3 4 5 6 7 8
Set range
0 – 9 (Binary input)
SW Bit No.
1 2 3 4 5
Auto
0 0 0 0 0
Light
1 0 0 0 0
Slightly light
0 1 0 0 0
Medium
0 0 1 0 0
Slightly dark
0 0 0 1 0
Dark
0 0 0 0 1
SW Bit No.
7 8
If the machine
information is
uncertain when set
to “Follows the
machine information”,
the metric size is
effective.
Inch size
1 0
Follows the machine
information.
0 1
Follows the machine
information.
1 1
SW4 Bit No.
1 2 3 4
0: Immediate
recall after
disconnection.
Set value
0 – 15 (Binary
input)
SW4 Bit No.
5 6 7 8
Set value
0 – 15 (Binary input)
DM-FX1
6 – 2