SW
NO.
Data
NO.
Item
Switch selection and contents of functions
Initial value
User
program
No.
Remark
SW5
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Signal send
level
Used to set the signal send level from the Modem. The
set range is 0 – 15 in the increment of 1dBm by binary
input. The value becomes – (Set value) – 5 dBm to the
actual in theory.
7 (–12
dBm)
0
6
1
7
1
8
1
SW6
1
ECM
Used to set whether ECM (Error Correction Mode) is
performed or not. When, however, SW52-7 (V.34 mode
function) is set to OFF, or when SW52-7(V.34 mode
function is set to ON and the transmission is not the
super G3 transmission, ECM Disable setup is effective.
This is because the ECM function is indispensable in a
transmission other than super G3 transmission in V.34
mode and the other party machine may perform
checking. With SW52-7 (V.34 mode function) is ON and
this reception function is disabled.
YES
1
Setup in
communication
other than V.34
2
ANSam (CED)
signal send
Used to set whether ANSam (CED) signal send is made
or not.
This is effective only when SW52-7
(V.34 mode
function) is OFF. This is because ANSam signal send is
indispensable in V.34 mode. (This machine uses the
ANSam signal also as the CED signal.)
YES
1
Effective only
when V.34
mode function
are disable.
3
CSI send
Used to set whether CSI signal send is perform or not.
The CSI signal includes the transmitter No.
YES
1
4
DIS reception
check in G3
send
Used to set whether DIS reception is checked or not in
G3 mode.
Once
when
receiving
NSF,
twice
when
receiving
DIS
0
5
None-
modulation
carrier in V.29
send
Used to set whether non-modulation carriers are sent or
not in V.29 transmission.
NO
0
6
EOL detection
timer
Used to set the detection timer of EOL (End Of Line) in
phase C reception.
13 sec
0
7
Countermeasure
for echo in
reception (CED
toner send
interval)
Used to set the time interval from CED sending to FSK
signal sending of DIS.
75 ms
0
If either of SW6-
7 or SW6-8 is
effective, open
of the line after
completion of
communication
is delayed by
1.5 sec.
8
Countermeasure
for echo in
transmission
Used to set the time interval from DIS reception to DCS
signal sending.
200 ms
0
SW5 Bit No.
5 6 7 8
Set value
0 – 15 (Binary input)
1: YES
0: NO
1: YES
0: NO
1: YES
0: NO
1: Twice
0: Once when receiving NSF, twice
when receiving DIS
1: YES
0: NO
1: 25 sec
0: 13 sec
1: 500 ms
0: 75 ms
1: 500 ms
0: 200 ms
DM-FX1