![Sharp DM-FX1 Service Manual Download Page 32](http://html.mh-extra.com/html/sharp/dm-fx1/dm-fx1_service-manual_367477032.webp)
SW
NO.
Data
NO.
Item
Switch selection and contents of functions
Initial value
User
program
No.
Remark
SW37
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
Reserved
1
7
Reserved
0
8
Reserved
1
SW38
1
Pause time
setup
Used to set the pause time. The set range is 1 sec to
15 sec by binary input. When set to 0, it is the same as
2 sec.
2 sec
0
103
When set to
“0000”, set to
“0010”.
2
0
3
1
4
0
5
Reserved
0
6
Reserved
0
7
Transfer
function
Used to set Enable/Disable of transfer of memory
reception image to another FAX when print is inhibited.
Enable
1
109
8
Reserved
0
SW39
1
Auto send call
time setup (T0
timer setup)
Used to set the call time when call does not reach the
other party in auto send mode. The set range is 30 – 60
sec in the increment of 5 sec by binary input of “(5 sec
×
N) + 30 sec)”.
“N” can be set in the range of 0 -7. When set to 7 (65
sec), it is the same as setup of 45 sec.
45 sec
0
116
When set to
“111”, set to
“011”.
2
1
3
1
4
Reserved
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW40
1
Number of
recall times in
case of an error
Used to set the number of recall times in case of a
communication error.
1 times
0
114
When set to 2
or more times,
set to 1.
2
0
3
0
4
0
5
0
6
0
7
0
8
1
SW38 Bit No.
1 2 3 4
Set range
1 – 15 sec in the increment of 1
sec (Binary input)
1: Enable
0: Disable
SW39 Bit No.
1 2 3
Set range
30 sec – 60 sec in the increment
of 5 sec (Binary input)
SW40 Bit No.
1 2 3 4 5 6 7 8
Set range
0 – 1 times (Binary input)
0: Recall inhibited
DM-FX1
6 – 15