AR-M236/M276/M237/M277 SIMULATION 8 - 11
Reset is not performed when the machine enters the aging
mode.
Operation/procedure
1.
Enter the interval aging cycle time (sec) with the 10-key pad.
Refer to SIM 7-1.
2.
Press the [START] key.
When the [START] key is pressed in aging, copying is performed con-
tinuously. This simulation is used to set the time interval between copy
operations in the unit of second.
This setting is valid when SIM 7-1 (Intermittent setting) is enabled.
Operation/procedure
1.
Warm-up starts by the cover open/close.
(Can be performed repeatedly by open/close of the cover.)
2.
The warm-up time is counted up and displayed in the unit of sec.
If the [CA] key is pressed at this time, count-up is interrupted to ter-
minate the simulation. (However, warm-up is continued.)
3.
After completion of warming up, "WARM UP COMPLETED" is dis-
played and the control returns to the initial screen.
Operation/procedure
1.
Touch the exposure mode to be changed.
The current set value is displayed.
2.
Enter the set value with the 10-key.
3.
Press the [START] key.
Output is made with the entered value, and the display returns to the
original state.
(
∗
) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
The minimum increment is 2V.
The result of (Set value – 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore, the set value entered must be an even number. If an odd
number is entered the entered odd 1 is displayed after
pressing [START] key.
Operation/procedure
1.
Touch the exposure mode to be changed.
The current set value is displayed.
2.
Enter the set value with the 10-key.
3.
Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
Min. unit: –25V increment
(
∗
) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
7-6
Purpose
Setting/Operation test/check
Function (Purpose)
Used to set the cycle of intermittent aging.
Item
Operation
Setting range
1-255
Default
3
7-8
Purpose
Setting/Operation test/check
Function
(Purpose)
Used to set the display of the warm-up time.
Item
Operation
8
8-1
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the
developing bias voltage in each copy mode and the
control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper
Item
Content
Installation
range
Default
1
AE
AE (
∗
)
200-550
400 (–400V)
2
TEXT
Character
450 (–450V)
3
TEXT/PHOTO
Character/Photo
450 (–450V)
4
PHOTO
Photo
450 (–450V)
5
SUPER/PHOTO
Super photo
400 (–400V)
6
TONER SAVE
Toner save
376 (–376V)
8-2
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the main
charger grid voltage (high mode) in each copy mode
and the control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor
Item
Content
Setting
range
Default
1
AE
AE (
∗
)
1-8
3 (–530V)
2
TEXT
Character
5 (–580V)
3
TEXT/PHOTO
Character/Photo
5 (–580V)
4
PHOTO
Photo
5 (–580V)
5
SUPER/PHOTO
Super photo
3 (–530V)
6
TONER SAVE
Toner save
2 (–505V)
NO.
Set value
Grid High
Grid Low
1 480
–480V
–350V
2 505
–505V
–375V
3
530
–530V
–400V