AR-M236/M276/M237/M277 SIMULATION 8 - 12
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
Operation/procedure
1.
Touch the exposure mode to be changed.
The current set value is highlighted.
2.
Enter the set value with the 10-key.
3.
Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
Min. unit: -25V increment
(
∗
) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
Operation/procedure
1.
Touch the exposure mode to be changed.
The current set value is displayed.
2.
Enter the set value with the 10-key.
3.
Press the [START] key.
Output is made with the entered value for 30sec, and the display
returns to the original state.
The minimum increment is 2V.
The result of (Set value – 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore, the set value entered must be an even number. If an odd
number is entered the entered odd 1 is displayed after
pressing [START] key.
4
555
–555V
–425V
5
580
–580V
–450V
6 605
–605V
–475V
7 630
–630V
–500V
8 655 –655V
–525V
8-3
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the main
charger grid voltage (low mode) in each copy mode
and the control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor
Item
Content
Setting
range
Default
1
AE
AE (
∗
)
1-8
3 (–400V)
2
TEXT
Character
5 (–450V)
3
TEXT/PHOTO
Character/Photo
5 (–450V)
4
PHOTO
Photo
5 (–450V)
5
SUPER/PHOTO
Super photo
3 (–400V)
6
TONER SAVE
Toner save
2 (–375V)
NO.
Set value
Grid High
Grid Low
1 480
–480V
–350V
2 505
–505V
–375V
3
530
–530V
–400V
4
555
–555V
–425V
5
580
–580V
–450V
6 605
–605V
–475V
7 630
–630V
–500V
8 655 –655V
–525V
NO.
Set value
Grid High
Grid Low
8-10
Purpose
Adjustment/Operation test/check
Function
(Purpose)
Used to check and adjust the operation of the
developing bias voltage in each printer mode and the
control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper
Item
Content
Installation
range
Default
1
DENS1(600)
Density 1 (600dpi)
200-550
400 (–400V)
2
DENS2(600)
Density 2 (600dpi)
450 (–450V)
3
DENS3(600)
Density 3 (600dpi)
450 (–450V)
4
DENS4(600)
Density 4 (600dpi)
450 (–450V)
5
DENS5(600)
Density 5 (600dpi)
500 (–500V)
6
TS(600)
Toner save (600dpi)
350 (–350V)
7
DENS1(1200) Density 1 (1200dpi)
300 (–300V)
8
DENS2(1200) Density 2 (1200dpi)
350 (–350V)
9
DENS3(1200) Density 3 (1200dpi)
376 (–376V)
10
DENS4(1200) Density 4 (1200dpi)
426 (–426V)
11
DENS5(1200) Density 5 (1200dpi)
500 (–500V)