AR-M236/M276/M237/M277 SIMULATION 8 - 4
24
7
Used to clear the OPC drum (membrane
decrease) correction counter. (This simulation is
executed when the OPC drum is replaced.
9
Used to clear the printer counter and other
counters. (The counter is cleared after completion
of maintenance.)
10
FAX counter data clear
15
Used to clear the scanner counter in the network
scanner mode.
25
1
Used to check the operation of the main drive
(excluding the scanner section) and to check the
operation of the toner concentration sensor. (The
toner concentration sensor output can be
monitored.) (To be supported for Ver.00.72 or
later)
2
Used to make the initial setting of toner
concentration when replacing developer.
26
1
Used to set whether the job separator is installed
or not. (Since this cannot be detected by hardware
detection, it is set in this simulation.)
2
Used to set whether the automatic detection of
paper size is made or not.
3
Used to set the specifications of the auditor.
Setting must be made depending on the use
condition of the auditor.
5
Used to set the count mode of the total counter
and the maintenance counter.
6
Used to set the specifications depending on the
destination.
10
Network scanner trial mode setting
12
Used to input the Software Key for E-MAIL RIC.
14
Used to input the Software Key for the PS
extension kit.
18
Used to set enable/disable of toner save operation.
22
Used to set the specification (language display) for
the destination.
30
Used to set ON/OFF of the heater lamp slow-up
control conforming to the CE mark control.
35
Used to set whether the same continuous troubles
are displayed as one trouble or the series of
troubles with SIM 22-4 when the same troubles
occur continuously.
36
Used to set whether the machine is stopped or not
when the maintenance counter life is expired.
41
Used to set ON/OFF of the automatic
magnification ratio selection (AMS) when setting
the binding function.
46
Used to set whether to meet with the output
direction of images regardless of the mode when
installing the finisher.
50
Used to set ON/OFF of the black and white
reversion function.
57
Used to set the model code.
60
Used to set enable/disable of the FAX mode key
when FAX is not installed. (When FAX is installed,
the FAX mode is enabled regardless of this setup.)
71
In the power save time setting, the pre-heat (pre-
heat mode setting) and the auto power shut off
time can be set to the short time setup (pre-heat: 1
min, auto power shut off: 4 min) and the long time
setup (pre-heat: 15min, auto power shut off:
60min).
27
1
Used to set PC/MODEM communication trouble
(U7-00) detection Yes/No.
5
Used to set the tag number.
Code
Function
Main
Sub
30
1
Used to display the sensor status attached to the
machine.
2
Used to display the status of the sensors attached
to the standard cassette and the manual feed tray.
(Use SIM 4-2 for the option cassettes.)
The sensor of an uninstalled cassette is not
displayed.
40
1
Used to check the sensor of the machine manual
feed tray.
2
Used to adjust the manual paper feed tray paper
width detector detection level.
3
The AD conversion value of manual feed width
detection is displayed.
41
1
Used to check the document size detection photo
sensor.
2
Used to adjust the detection level of the document
size photo sensor.
3
Used to check the light reception level and the
detection level of the original size detection photo
sensor.
4
Used to adjust the detection level of OC 20
degrees.
43
1
Used to set the fusing temperature in 600dpi,
1200dpi, or postcard print.
10
Used to set the paper feed cycle timing when
printing postcards.
44
1
Used to make various setups in each mode of
process control.
34
Used to set the transfer current value in each
mode.
35
Used to set the DV-Bias/Grid environment (low
temperature) correction temperature.
40
Used to set the time from the start of the main
motor rotation (Ready) to the start of toner supply
in previous rotation after turning on the power.
46
2
Used to set the exposure level in each exposure
mode.
7
Used to adjust the shift amount and the inclination
value for each level (1 to 5) of the exposure mode
(Super Photo).
9
Used to adjust the shift amount and the inclination
value for each level (1 to 5) of the exposure mode
(Text).
10
Used to adjust the shift amount and the inclination
value for each level (1 to 5) of the exposure mode
(Text/Photo).
11
Used to adjust the shift amount and the inclination
value for each level (1 to 5) of the exposure mode
(Photo).
12
FAX exposure level adjustment (1 mode automatic
adjustment)
13
FAX exposure level adjustment (Normal mode
individual adjustment)
14
FAX exposure level adjustment (Fine text mode
individual adjustment)
15
FAX exposure level adjustment (Super Fine mode
individual adjustment)
16
FAX exposure level adjustment (Ultra Fine mode
individual adjustment)
18
Used to adjust inclination for each exposure mode.
19
Used to set the control method of the exposure
mode.
20
Used to set the exposure correction value of SPF/
RSPF for OC exposure.
30
Used to set the AE and the limit value in AE (Toner
save).
Code
Function
Main
Sub