User’s guide
HRP/D
-
28
-
HS
Alterations
9
9.3
UPPER HEATING ELEMENT AND
PRESSURE BAR
9.3.1 Removal
1.
Disconnect the compressed air.
The top frame will now lower slowly, as the air escapes.
2.
Position the heating element or pressure bar so that there
is approximately 20 cm clearance.
(For positioning see Section
8
).
3.
Remove the wires from the terminals (only at the heating
elements).
Never use pliers. This could damage the terminals.
4.
Loosen the socket-head screws on the support bar clamps
on either side a few turns. (Use socket screw key
no. 6
).
5.
Slide the heating element or pressure bar diagonally (
5a
)
and lift it out of the top frame (
5b
).
Always have two people to do this.
20cm
3
2
4
5
a
5
b