User’s guide
HRP/D
-
40
-
HS
Tensioning and changing filament
13
9.
Slide the spring over the filament and slide the filament
through to the expanding pin.
10.
Slide the filament with expanding pin through the white
insulation sleeve of the pin block and pull it through as far
as possible.
11.
Then insert the end of the filament in the wire pin. Pull it
taut and tension the spring with pliers.
12.
Tighten the socket head screw.
(Use socket screw key
no. 2
).
13.
Switch on the machine and the control unit
corresponding to the replaced filament (switch
A
,
L
).
Then turn the temperature regulator (knob
T
) to the
highest position (position
100
).
The filament will then glow red.
Never touch the filaments and the reflectors when the
machine is in operation.
14.
Take hold of the end of the filament with pliers and
loosen the socket head screw one half turn. (Use socket
screw key
no. 2
).
15.
Pull the filament taut and tighten the socket head screw.
Check that the filament is straight. If not, repeat this
operation.
11
100