Connecting AC power
The G-4 Series standard version can operate on any 100–240V, 50/60 Hz AC mains power supply.
The G-4 Series maximum power consumption is 250W.
For temporary outdoor installations, connect the G-4 Series to AC power using the supplied cable with Neutrik powerCON TRUE1
NAC3FX-W (or similar), to ensure the correct ingress protection (IP-rating).
The mains cable must be fitted with a grounded connector intended for exterior use.The device must be grounded/earthed and able
to be isolated from AC power. The AC power supply must incorporate a fuse or circuit breaker for fault protection.
CAUTION!!
Do not open the fixture to replace the supplied power cable.
Do not connect the fixture to an electrical dimmer system, as doing so may cause damage.
When installing standard type C circuit breakers, there will be no limitations due to the fixture in-rush current.
For assistance with alternative configurations, contact your SGM representative.
After connecting the G-4 to power, run the on-board test, going to “MENU → TEST →AUTOMATED TEST”, to ensure the fixture and
each LED are functioning correctly. Please see “Control menu” on page 15
.
For permanent outdoor installations, the G-4 POI versions supplies a power cable with bare ends. Please refer to page 22 for
connecting AC power in POI fixtures. For POI, have a qualified electrician to wire the mains cable directly to a suitable branch circuit.
The junction’s ingress protection (IP-rating) must be suitable for the location.
PLEASE NOTE:
Both DMX-in and DMX-out must be connected in order to maintain the IP65-rating.
The G-4 Series without base and/or with ceiling mount bracket operates on 36V DC power and external power supply.
See in detail on page 18-19 how to install the ceiling mount bracket
.
The fixture must be grounded/
earthed and be able to be isolated
from AC power. The AC power
supply must incorporate a fuse or
curcuit breaker for fault protection.
Color
Black
White
green/yellow
Conductor
live
neutral
ground (earth)
Symbol
or
L
N
Wire
Figure 6: Connecting AC Power