16
Supported RDM functions
The G-4 Series features support for various RDM functions.
RDM (Remote Device Management) is a protocol enhancement to USITT DMX512 that allows bi-directional communication between
the fixtures and the controller over a standard DMX line. This protocol will allow configuration, status monitoring, and management.
You will need a RDM controller to get control over the supported parameters. See the tables below for supported RDM functions.
RDM functions
Please note:
The RDM controller communicates with the fixtures to show only the available options for each RDM function. The table is subject to change without notice.
RDM
Problem
Potential cause(s)
Remedies
Fixture does not respond or appears to be off.
No power to the fixture.
Confirm that the power is switched on, confirm the cables
are plugged in.
Main fuse is blown.
Contact SGM support or certified SGM service partner.
Fixture suddenly turned off.
Power was turned off.
Check the power supply, switches and breakers.
Fixture suddenly stopped responding.
The wireless transmitter or connections, was
disconnected / tampered with.
Inspect the wireless transmitter and connections.
DMX cables was disconnected.
Inspect DMX cables.
Fixture operates irregularly / abnormal.
DMX cable polarization is inverted (pin 2 + 3).
Install a phase-inverter or replace cables.
DMX link is not terminated.
Install a XLR 120ohm DMX termination at the end of
the DMX link.
Corrupted DMX cable.
Replace or repair defective cables and/or connections.
The fixture operates an internal program.
Go to MENU → MANUAL → STOP PROGRAM.
A corrupted fixture generates noise/disruptions on
the DMX link.
Track and isolate the corrupted fixture.
Color is uneven
The SGM Calibration Data set has been lost
Contact your local SGM dealer or [email protected].
Troubleshooting
Name
Sensor Type
Main Board Temperature
Temperature
Head Board Temperature
Temperature
Barndoor Temperature
(
only for G-4 Wash MBD)
Temperature
Light Source Temperature
Temperature
Pan Angle
Angle
Name
Sensor Type
Tilt Angle
Angle
Wireless Signal Strength
Other
Wireless Paired
Other
Mains Voltage
Voltage
Humidity
Humidity
Light PWM
( N.A. for G-4 Wash MBD)
Other
PID
Actions allowed
Name
0x0082
Device Label
0x0081
Manufacturer Label
0x00E0
DMX Personality
0x00E1
DMX Personality Description
0x0200
Sensor Definition
0x0201
Sensor Value
0x0080
Device Model Description
0x1001
Reset Device
PID
Actions allowed
Name
0x0051
Parameter Description
0x0090
Factory Defaults
0x0501
Display Level
0x0500
Display Invert
0x0400
Device Hours
0x0401
Lamp Hours
0x8626
SET
CRMX Log Off
Sensors
RDM enables various sensor readouts for remote device monitoring. See the table below for sensors and sensor types.
Please note:
The RDM controller communicates with the fixtures to show only the available sensors for this fixture.
The table is subject to change without notice.