background image

5

Safety information

• 

Do not open the device; there are no user-serviceable parts inside.

• 

Ensure that power is cut off when wiring the device to the AC mains supply.

• 

Ensure that the device is electrically connected to earth (ground).

• 

Do not apply power if the device or mains cable is in any way damaged. 

• 

Do not immerse the fixture in water or liquid.

DANGER!  Risk of electric shock. Do not open the device.

• 

Install in a location that prevents accidental contact with the device.

• 

Install only in a well-ventilated space. 

• 

Install at least 0.3 m (12 in.) away from objects to be illuminated. 

• 

Install only in accordance with applicable building codes. 

• 

Ensure a minimum clearance of 0.3m (12 in.) around the cooling fans.

• 

Do not paint, cover, or modify the device, and do not filter or mask the light. 

• 

Keep all flammable materials well away from the device.

• 

Allow the device to cool for 15 minutes after operation before touching it.

 

CAUTION:

 Exterior surface temperature after 5 min. operation = 45 °C (113 °F). Steady state = 68 °C (154 °F).

WARNING!  Take measures to prevent burns and fire.

•  Do not look directly at the light source from close range. 
• 

Take precautions to prevent injury due to falls when working at height. 

• 

For Permanent Outdoor Installations (POI), ensure that the fixture is securely fastened to a load-bearing surface with suitable 

corrosion-resistant hardware.

• 

For temporary installations with clamps, ensure that the quarter-turn fasteners are turned fully and secured with a suitable 

safety cable.

• 

For elevated installations, secure the fixture with suitable safety cables and always comply with relevant load dimensioning, 

safety standards and requirements.

• 

The standard safety wire cable must be approved for a safe working load (SWL) of 10 times the weight of the fixture, and 
it must have a minimum gauge of 4 mm.

WARNING!  Take measures to prevent personal injury.

WARNING! 

Read the safety precautions in this section before installing, powering, or operating 

this product.

SGM luminaries are intended for professional use only. They are not suitable for household use. 

Les luminaires SGM sont impropre à l’usage domestique. Uniquement à usage professionnel.

Review the following safety precautions carefully before installing or operating the device.

Summary of Contents for G-4 RGBAM WASH

Page 1: ...90mm 3 54in 157mm 6 18in 219mm 8 62in 277mm 10 92in 188mm 7 38in 255mm 10 02in 24mm 0 95in 201mm 7 91in 107mm 4 21in 220 465mm 18 30in 371mm 14 59in MOVING HEAD SERIES G 4 WASH POI G 4 W WASH G 4 WASH...

Page 2: ...ance on the information contained in this manual The SGM logo the SGM name and all other trademarks in this document pertaining to services or products by SGM or its affiliates and subsidiaries are tr...

Page 3: ...Calibration and Color Temperature Correction 13 Internal programs 13 Pan Tilt positions 13 Fixture properties 14 Control menu 15 RDM 16 Troubleshooting 16 Accessories 17 Ceiling mount bracket 17 G 4...

Page 4: ...4 G 4 Series dimensions G 4 Wash G 4 W Wash G 4 Wash G 4 W Wash with Top Hat All dimensions in milimeters and inches Drawing not to scale G 4 Wash Motorized Barndoors G 4 Wash Beam G 4 W Wash Beam...

Page 5: ...ING Take measures to prevent burns and fire Do not look directly at the light source from close range Take precautions to prevent injury due to falls when working at height For Permanent Outdoor Insta...

Page 6: ...000K with CTO filter inserted G 4 RGBAM also features Color filter macro used to mimic congo blue and deep saturated red Color filter emulating 89 LEE colors raw amber and raw mint Fully adjustable C...

Page 7: ...ersed in water or exposed to high pressure water jets It has adequate ventilation When using the fixture for outdoor events ensure that For wireless DMX or standalone operation the DMX out cable is se...

Page 8: ...ture The safety wire attachment point is designed to fit a carabine 6 Verify that there are no combustible materials cables or surfaces to be illuminated within a distance of 0 3 m 12 in from the fixt...

Page 9: ...ions contact your SGM representative After connecting the G 4 to power run the on board test going to MENU TEST AUTOMATED TEST to ensure the fixture and each LED are functioning correctly Please see C...

Page 10: ...nd simple verification of the input status Error indicator E If any errors are detected the message ERR will be flashing in the display for easy detection To read the error message go to MENU INFO ERR...

Page 11: ...n active wireless transmitter simultaneously as being connected to a cabled DMX The device will prioritize cabled DMX over the wireless DMX The active input type is displayed under the wireless signal...

Page 12: ...f 113 the following G 4 RGBAM in the DMX chain could then be set to a DMX address of 131 as the first fixture uses all the first 18 DMX channels including the channel 113 Therefore the next available...

Page 13: ...hosen position preset 5 Store overwrite the position preset by pressing ENTER The fixture will confirm when briefly snapping to green and back to white light 6 Repeat step 3 5 for other position prese...

Page 14: ...ies features a plus minus green function accessible from the color filter emulation channel Plus minus green feature allows the user to slightly change the amount of green used in the different color...

Page 15: ...gth Display the signal strength of the connection CRMX Paird Display CRMX Paird YES or NO DMX Active Display DMX Active YES or NO Display Flip X Press ENTER to enable disable X Display Off X Press ENT...

Page 16: ...link is not terminated Install a XLR 120ohm DMX termination at the end of the DMX link Corrupted DMX cable Replace or repair defective cables and or connections The fixture operates an internal progra...

Page 17: ...e components in the fixture Do not open other parts in the G 4 series as doing so might damage the ingress protection Contact your SGM dealer if the fixture operates abnormally is defective or needs a...

Page 18: ...rews tighten with 1Nm of torque 4 Mount the wire harness to the bracket ensure the connector is properly fitted 5 Insert the four screws tighten with 0 6Nm of torque NB Carefully observe that the orie...

Page 19: ...e sure it is well aligned 3 Insert the screw through the safety wire securing plate and the screw hole and tighten firmly 4 Fasten the snap hook in the safety wire clipping point if not already attach...

Page 20: ...ze of the luminaire does not change while using the zoom feature Like the traditional hand made Fresnel projectors the G 4 Wash Motorized Barndoors creates sharp defined shadows in flood position and...

Page 21: ...with 128mm and insert it into the filter grooves Attaching detaching the motorized barndoors Swapping the front lens of the G 4 Wash or Wash Beam for the motorized barndoors requires the replacement o...

Page 22: ...P rating of the G 4 Series it s highly recommended that the fixture is always vacuum tested after installing or swapping any part that might compromise the IP rating e g swapping the front lens or ins...

Page 23: ...g Tool Please contact SGM support if further help is needed Flashing orange when using a magnet fixture is ready to be connected to an external wireless transmitter Off fixture is off or indicator LED...

Page 24: ...nk in orange to show that it can be paired to a new transmitter Go to the wireless transmitter and press connect or link Now the external third party transmitter and the internal SGM receiver should b...

Page 25: ...2 DMX channels for test purposes Cleaning SGM luminaires with IP65 or IP66 rating do not need any cleaning procedures inside the fixture However cleaning the front lens may be needed to achieve the ma...

Page 26: ...r P N 07860040 1 x Omega bracket BL WH P N 83060602 83061206 SGM USB uploader cable P N 83062011 G 4 Wash Front Lens Kit BL P N 83061409 G 4 Wash Beam S 4 Micro Fresnel Front Lens Kit BL P N 83061410...

Page 27: ..._ ________________________________________________________________________________________________________ _____________________________________________________________________________________________...

Page 28: ...28 SGM Light A S Sommervej 23 8210 Aarhus V Tel 45 70 20 74 00 info sgmlight com www sgmlight com...

Reviews: