23
The POI versions are designed for permanent outdoor installations and are IP66-rated. POI versions are also designed for use in
maritime and offshore environments, as per the C5-M corrosion-resistance class.
Physical differences
The POI version differs from the standard version by having fixed-chassis power and DMX cables and heavy-duty cable glands.
The display and control panel have been removed.
Configuration
The POI version is configured exclusively via RDM (Remote Device Management), so the DMX start address, DMX mode, etc. have
to be configured via RDM. See “RDM” on page
16 for information
All DMX modes are the same as the standard G-4 Series. See all DMX charts available at www.sgmlight.com under the respective
products, or upon request via [email protected].
LED Indicator
The LED indicator is located on one side of the yoke (same place where the display is located in standard G-4 Series) and shows the
current status of the fixture.
The LED indicator has three different colors and three possible stages: static, flashing, or off.
• Static green:
fixture is powered on and receiving DMX signal.
• Flashing green:
fixture is powered on without receiving DMX signal.
• Flashing red:
an error message is stored, review via the SGM Service Tool or SGM RDM Addressing Tool.
Please contact SGM support if further help is needed.
•
Flashing orange (when using a magnet):
fixture is ready to be connected to an external wireless transmitter
• Off:
fixture is off or indicator LED is set to auto dimming.
Connecting DMX and AC power
DMX-in and DMX-out are in the same cable. See more in figure 23 about the SGM POI DMX cable.
Power is wired as the standard version. See “Connecting AC power” on page 9
.
For permanent installations, have a qualified electrician to wire the mains cable directly to a suitable branch circuit. The junction’s
ingress protection (IP) rating must be suitable for the location. For a temporary installation, the mains cable may be fitted with a
grounded connector intended for exterior use.
POI Permanent Outdoor Installation
1
2
XX
Max. 32 units/DMX line
XLR pin out
5 PIN XLR
DATA
GND
DATA -
DATA +
Shield / GND
White / DMX in / Data -
Red / DMX in / Data +
Shield / GND
Black / DMX out / Data -
Yellow / DMX out / Data +
Junction box
DMX cable
Shield / GND
White / DMX in / Data -
Red / DMX in / Data +
Shield / GND
Black / DMX out / Data -
Yellow / DMX out / Data +
Junction box
DMX cable
DMX termination last junction box
DMX cable
White / DMX in / Data -
Red / DMX in / Data +
Black / DMX out / Data -
Yellow / DMX out / Data +
120 Ohm +/- 5%
100- 240V AC
50-60 Hz
200W
100- 240V AC
50-60 Hz
200W
100- 240V AC
50-60 Hz
200W
Figure 24: Connecting DMX and AC Power for POI
SGM
SGM
SG
Shield
Wire
Color
White
Red
Conductor
Black
Yellow
Ground
DMX IN: Data -
DMX IN: Data +
DMX OUT: Data -
DMX OUT: Data +
SGM POI DMX Cable