113
Code Type
Code Length
All
All
Redundancy Level 3
Code types other than the following must be successfully read twice before
being decoded. The following codes must be read three times:
Code Type
Code Length
MSI Plessey
4 characters or less
D 2 of 5
8 characters or less
I 2 of 5
8 characters or less
Codabar
8 characters or less
Redundancy Level 4
The following code types must be successfully read three times before being
decoded:
< Redundancy Level 1 >
Redundancy Level 2
Redundancy Level 3
Redundancy Level 4
REDUNDANCY LEVEL
Code Type
Code Length
Codabar
8 characters or less
MSI
4 characters or less
D 2 of 5
8 characters or less
I 2 of 5
8 characters or less
Code Type
Code Length
All
All
Redundancy Level 1
The following code types must be successfully read twice before being
decoded:
Redundancy Level 2
The following code types must be successfully read twice before being
decoded: