Digital Weighing Indicator
SI 4100
G
TGZ[GTG
ଝ
ଝ
Weighing Mode 10 Accumulating Mode 2 (F21-10 Setting)
G
1.
SP1, SP2, SP3, SP4 can be any value.
ଖ
SP1, SP2, SP3, SP4 = 0, The relay is not used.
2. Finish relay output delay time(t1) setting : F-Function 22
3. Finish relay output “ON” time(t2) setting : F-Function 23
ଖ
Finish Relay will be “OFF”, after “t2” time set or weight is under “Empty Range”.
4. Relay Output
Relay
Contents
Relay
Contents
SP 1
Current weight < SP1(ON)
Current weight ≥ SP1(OFF)
SP 4
Current weight < SP1+SP2+SP3+SP4(ON)
Current weight ≥SP1+SP2+SP3+ SP4(OFF)
SP 2
Current weight < SP1+SP2(ON)
Current weight ≥ SP1+SP2(OFF)
FINISH
After time “t1”, “On”
during time “t2”
SP 3
Current weight < SP1+SP2+SP3(ON)
Current weight ≥SP1+SP2+ SP3(OFF)
Near
Zero
Within “EMPTY” range (ON)