background image

Digital Weighing Indicator 

SI 4100 

G

TG\GT

3. SPECIFICATION 

3-1. Analog Input & A/D Conversion 

Input Sensitivity 

0.3

 / Digit 

Load Cell Excitation 

DC 10V ( - 5V ~ + 5V ) 

Max. Signal Input Voltage 

Max.32mV 

Temperature Coefficient 

[Zero] ±16PPM/

 

[Span] ±3.5PPM/

 

Input Noise 

±0.3

 P.P 

Input Impedance 

Over 10

 

A/D Conversion Method 

Sigma-Delta 

A/D Resolution(Internal) 

520,000 Count(19bit) 

A/D Sampling Rate 

Max. 500times / Sec 

Non-Linearity 

0.005% FS 

Display Resolution(External) 

1/20,000 

3-2. Digital Part 

Display 

Parts 

Specification 

Display 

Main Display 

7Segments, 7digits VFD green Color 

Size :12.7(H) ×7.0(W)mm 

Min. Division 

×1, ×2, ×5, ×10, ×20, ×50 

Max. display value 

+999,950 

Under Zero value 

"-" (Minus display) 

Status lamp 

Steady, Zero, Tare,   

Run, Hold, Print, Comm. 

" ▼" Condition display Lamp 

SP1, SP2, SP3, SP4 , kg, g, t 

Green LED Display(3Ø) 

K e y 

Number, Function,   

CAL. Lock Key 

Number Key(10), Function(5),   

CAL. Lock keys (1pcs) 

3-3. General Specification 

Power Supply 

AC110/220V±10%), 50/60Hz, about 30VA 

Operating Temperature Range 

-10

 ~ 40

 

Operating Humidity Range 

Under 85% Rh (non-condensing) 

External Dimension 

200mm(W)

105mm(H)

165mm(L) 

Net Weight(kg) 

About 2.3kg 

Gross Weight(kg) 

About 3.0kg 

Ї

 AC 110V, Power supply is an optional before ex-factory. 

Create PDF

 files without this message by purchasing novaPDF printer (

http://www.novapdf.com

)

Summary of Contents for SI 4100

Page 1: ...G Digital Weighing Controller SI 4100 Instruction Manual 2010 May Ver 3 14 Create PDF files without this message by purchasing novaPDF printer http www novapdf com...

Page 2: ...page 21 page 6 Interface 6 1 Serial Interface RS 232C 6 2 Current Loop Interface 6 3 Print Interface Centronics Parallel Interface 6 4 Analog Output Interface 0 10V 6 5 Analog Output Interface 4 20mA...

Page 3: ...rotective Ground Earth terminal Prohibition of Operation process 1 3 Copy Rights 1 All Right and Authority for this Manual is belonged to Sewhacnm Co Ltd 2 Any kinds of copy or distribution without Se...

Page 4: ...the power of item 5 Avoid from water damage 6 For the improvement of function or performance we can change item specification without prior notice or permission 7 Item s performance will be up dated...

Page 5: ...ts 7digits VFD green Color Size 12 7 H 7 0 W mm Min Division 1 2 5 10 20 50 Max display value 999 950 Under Zero value Minus display Status lamp Steady Zero Tare Run Hold Print Comm Condition display...

Page 6: ...on Zero When the current weight is Zero Lamp is turn on Displayed weight is Zero Lamp is turn on Tare Tare function is set Lamp is turn on Tare Reset Lamp is turn off Run Weighing Batch is started La...

Page 7: ...rtain function No Press function No and press F key 3 Function key Refer Function keys To START or STOP weighing process First input SI 4100 Controller Starts weighing process and Second input SI 4100...

Page 8: ...Check set value Press this key Sp2 value will be display during 5sec Sp3 set value setting or Check Value setting Press this key set Sp3 value with No keys Press Enter and save new set value Check set...

Page 9: ...and move to next F function Press 1time to enter Calibration mode Function Keys Combined Key functions Function Key Contents Manual Discharge Remove remained material with manual discharge function Al...

Page 10: ...r installed for Optional Interface or Output Printer I F Analog out RS 422 485 or RS 232C two port LOAD CELL Connector N16 05 SERIAL I F RS 232C or CURRENT LOOP 9Pin D Type Female are built in as stan...

Page 11: ...nal Dimension Cutting Size External Dimension unit mm 4 2 Installation Components Power Cable Communication Connector D SUB 9P Load cell Cable G G G 94 188 186 165 105 200 162 92 3 Create PDF files wi...

Page 12: ...minimum It can make wrong weighing process caused by each load cell s variation 4 If there is some temperature difference around Load cell it can cause wrong weight measurement 5 Don t do Welding job...

Page 13: ...cs Load cell capacity 500kg Load cell Related output 2mV V Division 0 05kg Affirmation Voltage of Load cell 5 000mV Max Capacity of Weighing System 300kg Then estimation result for this weighing syste...

Page 14: ...P W is displayed you have input the pass word to start calibration mode G 1 At normal mode remove CAL BOLT on the Front panel 1 123 2 And press CAL LOCK S W inside Check the SET CAL Massage on display...

Page 15: ...f the value is over 20 000 Error message Err 01 will be displayed and move back CAPA mode again 9 When you press key the indicator starts to find Zero span deadG 10 Indicator will search DEAD weight d...

Page 16: ...5sec automatically Cal 2 0 16 After calculation span value displays on the display Please unload the test weight 0 629238G Caution The Test Weight s value must be at least 10 max capacity of weighing...

Page 17: ...Mode with SET CAL and press key to enter Simulation Calibration Mode with CELL CAL and start calibration mode with pressing key 1 At normal mode remove CAL BOLT on the Front panel 1 123 2 And press CA...

Page 18: ...ion 0 01 Input division 1 d 1G 9 press key to save the Digit Division value and move to next step d 1 Caution Max capacity value division value cannot be over 20 000 as Indicator resolution is 1 20 00...

Page 19: ...f load cell and input the measured value Then the weight measurement will be more precise than before 14 After inputing the value press key Calculated Span value will be displayed 0 087234 15 Press ke...

Page 20: ...return to F 01 If you move to certain function No press f function no with number key and press key Ex If you want to call F21 XX directly under F function mode Press and key and press key Then you ca...

Page 21: ...wind and dust there are small weight difference indicator will ignore the weight difference and display Zero For this compensation function indicator will estimate the weight difference is over the s...

Page 22: ...ction F10 G 0 Peak Hold Measure Max weight value and hold on display G 1 Sample Hold Hold current weight until Hold Reset External Input Selection F11 Set Value Input 1 Input 2 Input 3 Input 4 G 0 ZER...

Page 23: ...g F15 00 01 99 Automatic TARE reset time setting 00 not use 30 after 3 0sec Tare will reset Minus symbol display selection F16 G 0 Display symbol on the display G 1 Not use NEAR ZERO relay output mode...

Page 24: ...g Mode Weighing Mode Output1 Output2 Output3 Output4 Output5 Output6 1 Limit Mode 1 Sp1 ON Sp2 ON Sp3 ON Sp4 ON FINISH Near Zero 2 Packer Mode Sp1 Sp2 Sp3 Sp4 FINISH Near Zero 3 Check weighing Mode 1...

Page 25: ...time t1 setting F Function 22 3 Finish relay output ON time t2 setting F Function 23 Finish Relay will be OFF after t2 time set or weight is under Empty Range 4 Output Relay Relay Contents Relay Conte...

Page 26: ...nish relay output delay time t1 setting F Function 22 3 Finish relay output ON time t2 setting F Function 23 4 Relay Output Relay Contents Relay Contents SP 1 RUN input ON Current weight SP1 OFF SP4 R...

Page 27: ...Relay Contents Relay Contents SP 1 Near Zero Steady weight SP1 ON SP4 SP3 Steady weight SP4 ON SP 2 SP1 Steady weight SP2 ON OVER SP4 Steady weight ON SP3 SP2 Steady weight SP3 ON NEAR ZERO Within EMP...

Page 28: ...3 Relay Output Relay Contents Relay Contents SP 1 Near Zero Steady weight SP1 ON SP4 SP3 Steady weight SP4 ON SP 2 SP1 Steady weight SP2 ON OVER SP4 Steady weight ON SP3 SP2 Steady weight SP3 ON NEAR...

Page 29: ...time t1 setting F Function 22 3 Finish relay output ON time t2 setting F Function 23 Finish Relay will be OFF after t2 time set or weight is under Empty Range 4 Output Relay Relay Contents Relay Cont...

Page 30: ...ol displayed and you can process the weighing 2 Finish relay output delay time t1 setting F Function 22 3 Finish relay output ON time t2 setting F Function 23 Finish Relay will be OFF after t2 time se...

Page 31: ...yed and you can process the weighing 2 Finish relay output delay time t1 setting F Function 22 3 Finish relay output ON time t2 setting F Function 23 Finish Relay will be OFF after t2 time set or weig...

Page 32: ...SP3 Set value SP4 Relay ON Current Weight SP1 SP2 SP3 SP4 Set value 2 Finish relay output delay time t1 setting F Function 22 3 Finish relay output ON time t2 setting F Function 23 Finish Relay will b...

Page 33: ...g F Function 23 Finish Relay will be OFF after t2 time set or weight is under Empty Range 4 Relay Output Relay Contents Relay Contents SP 1 RUN input ON Current weight SP1 OFF SP 4 RUN input ON Curren...

Page 34: ...OFF after t2 time set or weight is under Empty Range 4 Relay Output Relay Contents Relay Contents SP 1 Current weight SP1 ON Current weight SP1 OFF SP 4 Current weight SP1 SP2 SP3 SP4 ON Current weig...

Page 35: ...02 05 setting F23 10 01 99 You can set duration time for FINISH relay 01 setting FINISH relay will be ON during 0 1sec 20 setting FINISH relay will be ON during 2 0sec STEADY Judging delay time t3 set...

Page 36: ...election F27 0 Absolute weight weighing mode 1 Positive weight weighing mode Manual Discharge selection Only for F21 02 Packer mode F28 0 Not use 1 Use Communication Mode setting Serial Port 1 Standar...

Page 37: ...ly F36 0 Stream Mode Weighing Data will be transferred continuously 1 Finish Mode When Finish Relay output only 1 time transferred 2 Manual Mode When Print key input 1 time transferred DATA Transferen...

Page 38: ...set value increased 1line will be added Paper Withdraw Rate setting After Continuous Single Print F46 3 1 9 Whenever set value increased 1line will be added Printing Language Selection If you install...

Page 39: ...sed 1 Using When connecting protocol with an appliance which uses frame by frame Caution When setting Command frame if F53 protocol frequency is high the speed of system can be slow In this case pleas...

Page 40: ...assword 4 numbers 2 If 2 display recheck the password 0000 is saved as basic password When setting password you cannot start SETUP mode without password do not forget your password Program Hard ware V...

Page 41: ...transferred data Serial Port Application Selection Under F62 00 setting only F65 0 DATA Transference purpose 1 Printing purpose Serial Printer DATA Transference Mode selection Under F62 00 F65 00 set...

Page 42: ...Type EIA RS 232C Communication Method Half Duplex Full Duplex Asynchronous Serial Baud Rate Selectable on F function31 Data Bit 8 No Parity mode only Bit Refer F30 Stop Bit 1 Parity Bit Non Even Odd S...

Page 43: ...play Un Steady Header 2 NT Net Weight GS Net Weight under TARE Data Bit Number 2B H Plus 2D H Minus 2D H Space 2E H Decimal Point Unit kg g t 6 1 5 Data Format 2 ID Number Data Transference Refer F fu...

Page 44: ...No Lamp Display Data 8 Space Weight Unit Header 1 OL Over Load Under Load ST Display Steady US Display Un Steady Header 2 NT Net Weight GS Net Weight under TARE Lamp Display Current Lamp Condition ON...

Page 45: ...ication About 100m long distance Current Loop Interface supports up to 9 600 Communication Speed only 6 2 1 Communication with Other Devices Remote Display External Display 6 2 2 Current Loop Circuit...

Page 46: ...Wire Connection Pin Signal Contents RE Pin Signal Contents RE 1 STROBE STROBE signal out 14 N C 2 DATA0 Data bit0 signal out 15 N C 3 DATA1 Data bit1 signal out 16 N C 4 DATA2 Data bit2 signal out 17...

Page 47: ...1 10 34 1 000 kg 01 10 35 1 000 kg 01 10 36 1 000 kg 01 10 36 1 000 kg 01 10 37 1 000 kg 01 10 38 1 000 kg 01 10 40 1 000 kg 01 10 41 1 000 kg 01 10 42 1 000 kg 01 10 43 1 000 kgG SUB TOTAL DATE 2006...

Page 48: ...o output is 0V and When the weight is Full capacity output is 10V If you need additional adjustment please adjust with VR1 Zero VR2 Span on the Analog Output PCB Remark This Analog option card convert...

Page 49: ...o this LO terminal do not be connected with other GND terminal on other devices 6 5 3 Output Adjustment This output is adjusted as when the weight is Zero output is 4mA and When the weight is Full cap...

Page 50: ...1 Signal Format Type RS 422 485 Format Baud Rate Refer F function 31 Data Bit 7 or 8 No Parity Stop 1 Parity Bit Even Odd No Parity Selectable Code ASCII STX 02H ETX 03H CR 0DH LF 0AH 1 LSB 0 1 2 3 4...

Page 51: ...option card can be applied on PLC Programmable Logic Controller or Score Board applications NPN TYPE Each Input circuit is isolated with Photo Coupler from external devices electrically G G F56 00 se...

Page 52: ...is BCD interface option card can be applied on PLC Programmable Logic Controller or Score Board applications Each Input circuit is isolated with Photo Coupler from external devices electrically Create...

Page 53: ...a Transfer STX ID NO RGRD P N 2byte Accumulated Count 6byte Accumulated Weight 11byte Weight unit 2byte ETX STX ID NO RSNO ETX S N Data Accumulated data S N Data Transfer For Current P N STX ID NO RSN...

Page 54: ...ETX TARE Reset ACK or NAK STX ID NO WPRT ETX Print ACK or NAK STX ID NO WSPR ETX SUB Total Print ACK or NAK STX ID NO WGPR ETX GRAND Total Print ACK or NAK STX ID NO WSTC ETX Delete SUB Total Data ACK...

Page 55: ...Load cell connection Check 3 Remove over loaded weight 7 2 Calibration Process Error Cause Treatment Err 01 When Max capacity digit value is over 20 000 Re input the Max Capacity less than 20 000 Max...

Page 56: ...d Setting Back up mode it can memory empty value and it becomes set value without displaying Un pass 1 If you set Normal Mode please check weighing part empty or not before turn on the power If there...

Page 57: ...rials in on weighing parts If you cannot remove materials please remove relay terminals Test 4 External Input Test Under TEST display press No 4 key and Enter TEST4 mode If you press External input S...

Page 58: ...ction or External damage caused by operator Any kinds of Mal function Defection caused by using spare part from Non Authorized Distributor or Agent Any kinds of Mal function Defection caused by not fo...