Digital Weighing Indicator
SI 4100
G
TG[`GTG
6-5. Analog Output Interface (Option 03 : 4~20mA Output)
This Option card converts weight value to Analog Electric Current output(4~20mA) and transfers to
external devices(Recorder, P.L.C), controlled by electric current output.
6-5-1. Specification
ཛ
Output Current : 4~20mA (Output Range : 2~22mA)
ཛྷ
Accuracy : More than 1/1,000
ཝ
Temperature Co-efficiency : 0.01%
ଇ
ཞ
Max. Loaded Impedance : Max. 500Ω
ଖ
When Weight display is “Zero”, 4mA current will be output, when Weight display is “Full Capacity”,
20mA current will be output.
6-5-2. Circuit
ଖ
“LO” terminal is not a “GND”, so this “LO” terminal
do not be connected with other “GND” terminal on other
devices.
6-5-3. Output Adjustment
ཛ
This output is adjusted as when the weight is “Zero”, output is “4mA” and When the weight is “Full
capacity”, output is “20mA”.
ཛྷ
If you need additional adjustment, please adjust with “VR1(Zero)”, “VR2(Span) on the Analog Output PCB.
ଖ
Remark
This Analog option card converts Displayed weight value(Micro-process data) to analog value on D/A
Converter(Digital to Analog converter)
This D/A Converter has Max. 1/4,000 accuracy, so this output is not suitable for high accuracy application, like
more than 1/3,000.
6-5-4. Connecter (9pin, “D-type” female)
9 pin D-type connector(Female)
Terminal Block (3 pin)
G
1 : HI(+), 5 : (-)
Create PDF
files without this message by purchasing novaPDF printer (
http://www.novapdf.com
)