![SEW-Eurodrive MOVIPRO ADC Operating Instructions Manual Download Page 175](http://html.mh-extra.com/html/sew-eurodrive/movipro-adc/movipro-adc_operating-instructions-manual_1250122175.webp)
9
Operation
Status and error messages
Operating Instructions – MOVIPRO
®
ADC
175
Status LED
Possible cause
Measure
Lights up
green
Online, operational mode and
connected
•
Online
•
Connection has been estab-
lished with a master.
•
Connection is active (estab-
lished state).
Flashing red
Minor fault or connection timeout
•
A correctable fault has oc-
curred.
•
A device error is active.
•
Polled I/O and/or bit-strobe I/
O connections are in timeout
state.
Lights up red Critical error or critical link failure
•
A correctable fault has oc-
curred.
•
BusOff status
•
DUP-MAC check has detec-
ted an error.
Status LED S2 PLC status
Status LED
Possible cause
Measure
Flashing
green
The firmware of the communica-
tion and control unit is running
correctly.
–
Flashing
green/orange
Data backup is created/restored.
–
Lights up or-
ange
Boot is active.
–
Flashing or-
ange
•
Firmware is being updated or
•
Bootloader update required.
–
Flashing red
•
SD card is not inserted.
•
File system on the SD card is
corrupt.
•
Boot process has failed.
Switch the device off and back on
again. Consult
SEW‑EURODRIVE service if the
error reoccurs.
Status LED S3
Status LED
Possible cause
Measure
Lit green
User program is running.
–
Flashing
green
•
Program sequence has
stopped.
•
Bootloader update required.
Start the user program.
Off
No program is loaded.
Load an user program into the
communication and control unit.