![SEW-Eurodrive MOVIPRO ADC Operating Instructions Manual Download Page 110](http://html.mh-extra.com/html/sew-eurodrive/movipro-adc/movipro-adc_operating-instructions-manual_1250122110.webp)
7
Electrical installation
Electrical connections
Operating Instructions – MOVIPRO
®
ADC
110
Phase reversal cable
INFORMATION
If you are using an encoder, note that you also need an encoder signal reversal cable
in addition to the phase reversal cable. For more information about encoder signal re-
versal cables, refer to the description of the encoder connection.
11 kW (IEC/UL)
Cable
Length/installation
type
Type
Wiring diagram
Part number: 18119638
Han
®
10 B ↔ Han
®
10 B
Fixed length
D/6.0
U1 – V1
V1 – U1
W1 – W1
13 – 13
14 – 14
15 – 15
TF+ – TF+
TF- – TF-
15 kW, 22 kW (IEC/UL)
Cable
Length/installation
type
Type
Wiring diagram
Part number: 18113745
Han
®
10 B ↔ Han
®
10 B
Fixed length
D/10.0
U1 – V1
V1 – U1
W1 – W1
13 – 13
14 – 14
15 – 15
TF+ – TF+
TF- – TF-
7.12.9
X2301: Braking resistor
Function
Power connection for external braking resistor
Connection type
Han
®
Q 5/0, female
22749055/EN – 04/2016