7
Electrical installation
Electrical connections
Operating Instructions – MOVIPRO
®
ADC
123
7.12.14 X3222: Multi-distance encoder
Function
Connection for HIPERFACE
®
, SSI, sin/cos, TTL, HTL and RS422 encoders
Connection type
M23, insulator, P part, 12-pin, female, +20°-coded
Wiring diagram
8
12
7
6
5
11
4
3
2
10
1
9
No.
Name
Function
1
CLK (C)
Clock line (Signal track C (K0))
2
/CLK (/C)
Negated clock line (Negated signal track C (/K0))
3
A
Signal track A (K1)
4
/A
Negated signal track A (/K1)
5
B
Signal track B (K2)
6
/B
Negated signal track B (/K2)
7
Data-
Data line (-)
8
Data+
Data line (+)
9
GND
Reference potential
10
+24V
DC 24 V output
Total current load of DC 24 V encoder supply
≤ 400 mA
11
GND
Reference potential
12
+12V
DC 12 V output
Total current load of DC 12 V encoder supply
≤ 650 mA