6
Service
Fault messages and list of faults
Compact Operating Instructions – MOVIDRIVE
®
MDX60B/61B
53
Fault
Subfault
Code Designation Response
(P)
Code
Designation
Possible cause
Measure
122
"Absolute en-
coder option"
Immediate
stop
61
X15: Critical transmitter
current
Soiled, transmitter broken
Replace encoder
16445
X14: Critical transmitter
current
62
X15: Critical encoder tem-
perature
Encoder temperature too high
Reduce motor and ambient
temperature
16446
X14: Critical encoder tem-
perature
259
X15: Insufficient clock fre-
quency
Incorrect encoder parameteri-
zation
Check encoder parameteriza-
tion
260
X15: Encoder signals pro-
grammable fault
576
X15: Internal encoder
warning
769
X15: Encoder signals pro-
grammable fault
16643
X14: Insufficient clock fre-
quency
16644
X14: Encoder signals pro-
grammable fault
16960
X14: Internal encoder
warning
17153
X14: Encoder signals pro-
grammable fault
771
X15: Emergency signal
17155
X14: Emergency signal
123
Positioning
interruption
Emergency
stop (P)
0
Fault "Positioning/Position-
ing interruption"
Target monitoring when inter-
rupted positioning process is
resumed. Target would be
overrun.
Perform positioning process
without interruption until it is
complete
124
Ambient con-
dition
Emergency
stop (P)
1
Permitted ambient temper-
ature exceeded
Ambient temperature > 60 °C
• Improve ventilation and
cooling conditions
• Improve air supply to the
control cabinet; check filter
mats
24770531/EN – 11/2017