33
Fault
Subfault
Code Designation Response
(P)
Code
Designation
Possible cause
Measure
98
CRC fault
Immediate
stop
0
"CRC via internal flash"
fault
Internal device fault flash
memory defective.
Sending in a device for repair
99
IPOS ramp
calculation
Immediate
stop
0
"Ramp calculation" fault
Only in IPOS
PLUS®
mode:
Positioning ramp is sinusoidal
or square and an attempt is
made to change ramp times
and traveling velocities with en-
abled inverter.
Rewrite the IPOS
PLUS®
pro-
gram so that ramp times and
traveling velocities can only
be altered when the inverter is
inhibited.
100
Vibration –
warning
Display fault
(P)
0
Vibrations diagnostics
warning
Vibration sensor warning (→
"DUV10A" operating instruc-
tions)
Determine cause of vibra-
tions. Continue operation until
F101 occurs.
101
Vibration fault Rapid stop
(P)
0
Vibration diagnostics fault Vibration sensor signals fault
SEW‑EURODRIVE recom-
mends that you remedy the
cause of the vibrations imme-
diately
102
Oil aging
warning
Display fault
(P)
0
Oil aging warning
Warning signal from the oil
aging sensor
Schedule oil change
103
Oil aging fault Display fault
(P)
0
Oil aging fault
Fault message from the oil
aging sensor
SEW-EURODRIVE recom-
mends that you change the
gear unit oil immediately.
104
Oil aging – o-
vertempera-
ture
Display fault
(P)
0
Oil aging overtemperature Overtemperature signal from
the oil aging sensor
• Let oil cool down
• Check if the gear unit cools
properly
105
Oil aging
ready signal
Display fault
(P)
0
Oil aging ready signal
Oil aging sensor is not ready
for operation
• Check voltage supply of oil
aging sensor
• Check and, if necessary,
replace the oil aging sensor
106
Brake wear
Display fault
(P)
0
Brake wear fault
Brake lining worn
Replace brake lining (→ "Mo-
tors" operating instructions).
107
Line compon-
ents
Immediate
stop
1
For regenerative power
supply only: No feedback
signal from main contactor
Main contactor defective
• Check main contactor
• Check control cables.
108
DCS fault
Display fault 0
DCS fault
1
Configuration data not
loaded correctly to DCS..B
option.
Connection interrupted while
loading the program to the
DCS..B option.
• Reload the configuration
files.
• Then switch the DCS..B op-
tion off and on again.
2
Invalid configuration data
for software version of the
DCS..B option.
DCS..B option configured using
a wrong software version.
• Configure the DCS..B op-
tion with the permitted
MOVISAFE
®
software ver-
sion.
• Then switch the DCS..B op-
tion off and on again.
3
Unit was programmed with
incorrect software inter-
face.
Program or configuration data
was loaded into the unit with an
incorrect MOVISAFE
®
software.
• Check the DCS..B version
and parameterize it again
using a valid MOVISAFE
®
software.
• Then switch the DCS..B op-
tion off and on again.
4
Incorrect reference voltage • Incorrect reference voltage
• Faulty supply voltage of the
DCS..B option
• Faulty component on the
DCS..B option
• Check supply voltage of
DCS..B option.
• Switch DCS..B option off
and on again.
5
6
Faulty system voltage
• Faulty supply voltage of the
DCS..B option
• Faulty component on the
DCS..B option
• Check supply voltage of
DCS..B option.
• Switch DCS..B option off
and on again.
7
10
Incorrect supply voltage.
• DC 24 V supply voltage of
the DCS..B option is faulty.
• Faulty component on the
DCS..B option
• Check supply voltage of
DCS..B option.
• Switch DCS..B option off
and on again.
24770531/EN – 11/2017