Manual – Controllers DHE/DHF/DHR21B (standard) and DHE/DHF/DHR41B (advanced)
61
5
Communication via Ethernet
Project Planning and Startup with MOVITOOLS
®
MotionStudio
Adjusting located
Ethernet stations
to the network
(addressing)
Proceed as follows to adjust (address) the localized Ethernet stations to the network:
1. Double-click the "Communication parameters" area of the respective unit [1].
You can now change the following settings:
•
IP address of the Ethernet station
•
IP address of the subnet mask
•
IP address of the standard gateway
•
DHCP startup configuration (if supported by the unit)
2. Transmit the address changes to the Ethernet station. Click on [Download] [2].
3. Switch the unit off and on again in order to apply the changes.
Setting the
engineering PC to
the network
(addressing)
To the following to adapt the engineering PC to the network setting (addressing):
1. Select the following item from the Windows start menu:
[Start] / [Setup] / [Network connections]
2. Select the corresponding PC interface.
3. Select "Properties" from the context menu.
4. Activate the checkbox with the entry "Internet protocol (TCP/IP)".
5. Click on "Properties".
6. Activate the "Use the following IP address" checkbox.
7. Enter the same IP addresses for the subnet mask and the standard gateway as for
the other Ethernet stations in this local network.
9007200786544907
[1] "Communication parameters" window
[2] "Download" button
[1]
[2]