www.servware.com
800•768•5953
IMPORTANT
To perform gas conversion, a licensed and qualified technician is required.
Service, Installation & Care Manual
12
2.6 Gas Conversion Instruction
The
Standard/Convection Industrial Range with Oven
is produced to use LPG or NG
gas. Then check to see if the gas used in your region is compatible with the type of
gas for which the product was manufactured. If not, gas must be converted to Natural
Gas (LN) or Liquefied Petroleum Gas (LPG). To do this, you must purchase from the
company, separately from the product, the gas conversion kit containing the range and
oven injectors and the ranee spreader.
For conversion the following guidelines should be followed:
1. Close the manual gas valve and disconnect the equipment from gas network, making
sure that there is no leakage. Then remove the pressure regulator from the gas inlet
on the equipment to make work easier.
2. Remove the knobs, thermostat
(1)
and the equipment's waste drawer
(2)
.
3. To remove the panel
(4)
from the equipment, it is necessary to remove the two
screws
(3)
from the front of the panel with the aid of a screwdriver, after simply
detatching the panel from the equipment.
4. Remove grills
(10)
, flame spreaders
(9)
, and
(8)
.
5. Remove the screws that secure the distribution tube inside the equipment with a
double screwdriver.
6. Remove the dispensing tube
(5)
and then pull the dispensing tube all the wat in. out
(horizontally) and place it on a flat surface. It is ideal that this step is carried out by
two or more people.
7. In place of the removed gas injectors
(6)
, place the new injectors that are in the
accessory kit. But first apply some pipe sealant to the valve thread and the screw-in
the new injectors to the correct gas type.
8. To change the oven injector, open the movable bottom panel and remove the
screws
(11)
form the injector holder
(12)
.
9. Remove the injectors
(13)
with a 1/2" wrench.
10. Repeat the same procedure as 7, but now for the range.
02. EQUIPMENT INSTALLATION