www.servware.com
800•768•5953
Service, Installation & Care Manual
17
02. EQUIPMENT INSTALLATION
2.13 Turning on the Equipment - Product Ignition
1. Open the manual gas supply valve (which will release gas into the equipment).
2. Light the burner pilot until the flame ignites, repeat on all others (see image below).
Note:
The ignition order does not interfere with the use of the equipment.
3. Turn the knob which you want counterclockwise (through the knob adjusts the flame).
4. Make sure the burner is lit. If the burner does not light, repeat the procedure.
5. After lighting all burners, you can turn off the main burners and turn them back on simply by
turning the corresponding knobs.
Note:
The pilot burner flame is factory set according to the gas for which the equipment was
originally manufactured. Always check that the pilot burner flame is lit. If it is not, perform
the procedures described above again.