Section 3 Docking Station & PC Software Operations
Io
SENSOR
44
SMT-200 Operations and Technical Manual 2.00/R1
3.8.3
The SMT-200 During File Transfer
Phase 1:
Upl INFO200.TXT
Uploading the files status from the SMT-200
8 Blocks CRC
Only this file is sent in 128 byte blocks
COM1,19200 baud
at 19200 baud
Mem: 325904
free memory
Phase 2:
Dnl INFOHOST.TXT
Downloading a script file from the PC Host
0 Blocks CRC
all files are sent in 1k blocks with CRC checking
Received #
COM1,115200 baud
at 115200 baud
Mem: 281872
free memory
Phase 3:
Time and date are synchronised
Phase 4:
All files to be updated are processed in the same way
3.8.4 Failing
Transfers
A failing transfer can have several causes:
•
Incorrect COM port selection, try another COM port (i.e. select COM 1 or COM 2).
•
The SMT-200 to Docking Station cable is not connected properly.
•
Docking Station's power is off: the SMT-200 will be switched on however, but the
communications circuit needs power.
•
PC is not ready, i.e. other processor tasks are taking too long, causing time-out errors.
Preferably run the Docking Station software under DOS if transfer problems are found. It has
been proved that it will work successfully under Windows 3.1. Windows 95 will run the
software but this has been found to be system dependent. Try running the software in MS-
DOS mode.
•
Some problems have been encountered with incompatible serial interface controllers on
certain computers. If all the above fails then try a different computer, if available.